A Wearable Multimodal Sensor for Simultaneous and Co‐Located Muscle Electrophysiological and Mechanical Monitoring
Advanced Healthcare Materials · 2026
DOI: 10.1002/adhm.202504778 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von Peng Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hebei University of Technology, Tianjin, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Electromyography, Muscle, Skeletal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 76 Literaturangaben. Gefördert von: National Key R&D Program of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Simultaneous and spatially aligned acquisition of electrical and mechanical muscle signals is essential to accurately capture neuromechanical coupling between neural activation and mechanical output. However, existing multi‐device methods face issues like non‐simultaneous recordings, spatial deviation, and complex setups that complicate data collection and compromise integrity. Here, we present a wearable multimodal sensor that simultaneously acquires surface electromyography (sEMG), surface muscle pressure (SMP), and mechanomyography (MMG) at the same location using a single sensing material and integrated structure. This long‐term stable system demonstrates high signal‐to‐noise ratio (SNR, 27.4 dB) and reusability for electrophysiological recordings, along with excellent mechanical performance, including low detection limit (≈25 Pa), broad pressure range (0–320 kPa), and fast response (≈16 ms). System‐level validation across exercise, fatigue, and rehabilitation scenarios confirms robust capture of muscle neuromechanical dynamics. This work provides a high‐performance yet simplified platform for wearable muscle monitoring, with potential impact in rehabilitation robotics and human–machine interfacing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China.
- Institute of Engineering and Applied Technology, Fudan University, Shanghai, China.
- School of Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China.
ORCID-Profile: Peng Wang, Jixiao Liu, Funing Hou, Dianpeng Qi
Förderung
- National Key R&D Program of China
- National Key Research and Development Program of China
Zitieren
APA
Wang, P., Liu, J., Gao, S., Hou, F., Ma, C., Liang, C., Cui, L., Qi, D., & Guo, S. (2026). A Wearable Multimodal Sensor for Simultaneous and Co‐Located Muscle Electrophysiological and Mechanical Monitoring. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202504778
Vancouver
Wang P, Liu J, Gao S, Hou F, Ma C, Liang C, et al. A Wearable Multimodal Sensor for Simultaneous and Co‐Located Muscle Electrophysiological and Mechanical Monitoring. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.202504778
BibTeX
@article{Wang2026,
author = {Wang, Peng and Liu, Jixiao and Gao, Song and Hou, Funing and Ma, Cong and Liang, Cuiyuan and Cui, Longlong and Qi, Dianpeng and Guo, Shijie},
title = {A Wearable Multimodal Sensor for Simultaneous and Co‐Located Muscle Electrophysiological and Mechanical Monitoring},
journal = {Advanced Healthcare Materials},
year = {2026},
doi = {10.1002/adhm.202504778}
}