Bioprinted Collagen Cell Constructs with Gradient BMP‐2‐Loaded Microbeads for Rotator Cuff Tear Regeneration
Advanced Healthcare Materials · 2026
DOI: 10.1002/adhm.202504150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von WonJin Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Precision Medicine, Sungkyunkwan University School of Medicine (SKKU-SOM), Suwon, 16419, Republic of Korea. Hauptthemen laut MEDLINE: Bone Morphogenetic Protein 2, Rotator Cuff Injuries, Microspheres, Collagen. Die Arbeit nennt 83 Literaturangaben. Gefördert von: Korea National Institute of Health, National Research Foundation of Korea.
Abstract (Originalsprache)
In rotator cuff tears (RCT), surgical intervention is often required to restore damaged tissues because of their limited self‐healing capacity. However, surgical treatments often fail to completely restore RCT, particularly in forming their interface regions. Therefore, the development of effective tissue‐engineering‐based treatments is increasingly necessary to encourage the formation of a bone‐to‐tendon interface (BTI). This study proposes a cell construct bioprinted using a stem cell‐loaded collagen bioink supplemented with collagen methacrylate microbeads (CMA‐beads) as a bone morphogenic protein 2 (BMP‐2) carrier to support the restoration of torn bone‐to‐tendon complex tissue. To obtain a bioink containing BMP‐2 carriers, a water‐in‐oil (W‐O) emulsion technique is applied. The CMA‐beads sustained the release of BMP‐2 in the collagen‐based bioink and promoted the cellular activity and osteogenesis of bioprinted stem cells in vitro. A multi‐layered construct containing bone, graded structure‐1 and ‐2, and tendon regions with different pore sizes is fabricated using a core‐shell nozzle‐assisted bioprinter. The BMP‐2 content gradually decreased from the bone to the tendon tissue region by varying the flow rate ratio of each bioink in the core and shell regions. The implantation of the cell‐constructs in a rabbit full‐thickness partial‐width RCT (FTPWRCT) model significantly accelerated the remodeling of full‐thickness bone‐to‐tendon tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Precision Medicine, Sungkyunkwan University School of Medicine (SKKU-SOM), Suwon, 16419, Republic of Korea.
- Department of Convergence Pharmaceutical Science, Korea University, Sejong, 30019, Republic of Korea.
- Department and Research Institute of Rehabilitation Medicine, College of Medicine, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
- Department of Biotechnology and Bioinformatics, Korea University, Sejong, 30019, Republic of Korea.
- Department of Anatomy, Catholic University of Daegu School of Medicine, Daegu, 42472, Republic of Korea.
- Department of Biochemistry, College of Medicine, Soonchunhyang University, Cheonan, 31151, Republic of Korea.
ORCID-Profile: GeunHyung Kim
Förderung
- Korea National Institute of Health
- National Research Foundation of Korea
Zitieren
APA
Kim, W., Lee, S. C., Lee, H., Moon, Y. S., Lee, Y. J., Kwon, D. R., & Kim, G. (2026). Bioprinted Collagen Cell Constructs with Gradient BMP‐2‐Loaded Microbeads for Rotator Cuff Tear Regeneration. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202504150
Vancouver
Kim W, Lee SC, Lee H, Moon YS, Lee YJ, Kwon DR, et al. Bioprinted Collagen Cell Constructs with Gradient BMP‐2‐Loaded Microbeads for Rotator Cuff Tear Regeneration. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.202504150
BibTeX
@article{Kim2026,
author = {Kim, WonJin and Lee, Sang Chul and Lee, Hyeongjin and Moon, Yong Suk and Lee, Yoon-Jin and Kwon, Dong Rak and Kim, GeunHyung},
title = {Bioprinted Collagen Cell Constructs with Gradient BMP‐2‐Loaded Microbeads for Rotator Cuff Tear Regeneration},
journal = {Advanced Healthcare Materials},
year = {2026},
doi = {10.1002/adhm.202504150}
}
EUVIMED