Plug‐and‐Play Centrifuge‐Only Device for Rapid Sepsis Diagnosis
Advanced Healthcare Materials · 2025-12 · 14 (32)
DOI: 10.1002/adhm.202503651 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 02.09.2025. Verfasst von Mohammad Osaid und 5 weiteren Autor:innen. Beteiligte Einrichtung: Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, 100 44, Sweden. Hauptthemen laut MEDLINE: Sepsis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Foundation for Strategic Research (SSF).
Themen: Sepsis
Abstract (Originalsprache)
Sepsis is a time‐critical condition causing over 13 million deaths annually, with each hour of treatment delay in patients with septic shock increasing mortality by 8%. Rapid pathogen identification is crucial, yet current workflows depend on multiple culture steps that delay pathogen identification and targeted treatment by days. A plug‐and‐play, fully automated centrifuge tube is presented that isolates and concentrates bacteria directly from blood or blood culture using only conventional lab centrifuges. Each tube can process 7.5 ml of sample and yields, within 40 min, a 0.7 mL clear suspension with greater than threefold enhanced bacteria concentration and 99.9% blood cell rejection, ready for downstream detection. It is demonstrated that this approach supports key diagnostic workflows, including 1) a novel isolate‐then‐culture strategy detecting bacterial concentrations as low as 10 CFU/mL; 2) direct matrix‐assisted laser desorption ionization time‐of‐flight (MALDI‐TOF) identification, bypassing subculturing, and; 3) microfluidic single‐cell detection. This fully automated platform is compatible with existing centrifuges, is anticipated to facilitate broader adoption in routine clinical practice, while its ability to enable rapid, same‐workshift bacterial enhancement can reduce diagnostic time by about one day in the context of time‐critical sepsis diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, 100 44, Sweden.
- Department of Clinical Microbiology, Karolinska University Hospital, Huddinge, 141 86, Sweden.
ORCID-Profile: Mohammad Osaid, Volkan Özenci, Wouter van der Wijngaart
Förderung
- Swedish Foundation for Strategic Research (SSF)
Zitieren
APA
Osaid, M., Marino Miguélez, M. H., Bayrak, B., Özmen-Capin, B. B., Özenci, V., & van der Wijngaart, W. (2025). Plug‐and‐Play Centrifuge‐Only Device for Rapid Sepsis Diagnosis. Advanced Healthcare Materials, 14(32). https://doi.org/10.1002/adhm.202503651
Vancouver
Osaid M, Marino Miguélez MH, Bayrak B, Özmen-Capin BB, Özenci V, van der Wijngaart W. Plug‐and‐Play Centrifuge‐Only Device for Rapid Sepsis Diagnosis. Advanced Healthcare Materials. 2025;14(32). doi:10.1002/adhm.202503651
BibTeX
@article{Osaid2025,
author = {Osaid, Mohammad and Marino Miguélez, M Henar and Bayrak, Berke and Özmen-Capin, Büsra Betül and Özenci, Volkan and van der Wijngaart, Wouter},
title = {Plug‐and‐Play Centrifuge‐Only Device for Rapid Sepsis Diagnosis},
journal = {Advanced Healthcare Materials},
year = {2025},
volume = {14},
number = {32},
doi = {10.1002/adhm.202503651}
}
EUVIMED