EUVIMEDEUVIMED entdecken
Crossref

Nanofibrous Electrospun Patches Fabricated from Biodegradable Polyesters Provide Effective Hemorrhage Control

Prathamesh Mane iD, Avanti Pandit iD, Mahdi Zafari iD, Joshua Menefee iD, Christopher W Barney iD, Ge Zhang, Abraham Joy iD

Advanced Healthcare Materials · 2025

DOI: 10.1002/adhm.202503397 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Prathamesh Mane und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Interdisciplinary Science and Engineering Center, Northeastern University, 805 Columbus Ave, Boston, MA, 02120, USA. Hauptthemen laut MEDLINE: Nanofibers, Polyesters, Hemorrhage, Hemostatics. Die Arbeit nennt 61 Literaturangaben. Gefördert von: U.S. Department of Defense CDMRP Discovery Award.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Uncontrolled hemorrhage is the leading cause of preventable death in both civilian and military populations. Current topical hemostats rely on packing the wound cavity, and/or applying external pressure with pelvic binders. These methods have complications, need extensive training, necessitate surgical removal of hemostats, and lack an understanding of the chemical structure‐hemostatic property relationships. This work describes the design and testing of hemostatic electrospun patches (EPs) with carboxylic acid (–COOH) and primary amine (–NH 2 ) as procoagulant functional groups. EPs accelerate whole blood clotting in vitro, with –COOH EPs performing almost twice as better compared to –NH 2 EPs. In a mouse liver hemorrhage model, the EPs lower bleeding times by about 3 times compared to cotton gauze as control. The EPs restrict blood component flow and form a contracted, tissue‐adhesive clot at the EP–wound interface due to its nanofibrous nature, thus mediating wound closure. On the other hand, cotton gauze fails to form a contracted clot at the gauze–wound interface leading to open rebleeding wounds upon material removal. Among the EPs, wound closure and clot‐mediated tissue adhesion are influenced by the chemical functionality of polyesters with –COOH EPs performing better than –NH 2 EPs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NanofibersPolyestersHemorrhageHemostaticsAnimalsMiceBlood CoagulationMale

Stichwörter der Autor:innen

clot contractioncotton gauzeelectrospun nanofiberhemorrhage controlhemostatic materialprocoagulant chemistry

Substanzen

PolyestersHemostatics

Autor:innen und Institutionen

  • Department of Bioengineering, Interdisciplinary Science and Engineering Center, Northeastern University, 805 Columbus Ave, Boston, MA, 02120, USA.
  • School of Polymer Science and Polymer Engineering, Goodyear Polymer Center, University of Akron, 170 University Ave, Akron, OH, 44325, USA.
  • Department of Biomedical Engineering, Olson Research Center, University of Akron, 260 S Forge St, Akron, OH, 44325, USA.

ORCID-Profile: Prathamesh Mane, Avanti Pandit, Mahdi Zafari, Joshua Menefee, Christopher W Barney, Abraham Joy

Förderung

  • U.S. Department of Defense CDMRP Discovery Award

Zitieren

APA

Mane, P., Pandit, A., Zafari, M., Menefee, J., Barney, C. W., Zhang, G., & Joy, A. (2025). Nanofibrous Electrospun Patches Fabricated from Biodegradable Polyesters Provide Effective Hemorrhage Control. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202503397

Vancouver

Mane P, Pandit A, Zafari M, Menefee J, Barney CW, Zhang G, et al. Nanofibrous Electrospun Patches Fabricated from Biodegradable Polyesters Provide Effective Hemorrhage Control. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202503397

BibTeX
@article{Mane2025,
  author = {Mane, Prathamesh and Pandit, Avanti and Zafari, Mahdi and Menefee, Joshua and Barney, Christopher W and Zhang, Ge and Joy, Abraham},
  title = {Nanofibrous Electrospun Patches Fabricated from Biodegradable Polyesters Provide Effective Hemorrhage Control},
  journal = {Advanced Healthcare Materials},
  year = {2025},
  doi = {10.1002/adhm.202503397}
}
Kostenlos starten →