EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Ultra‐Flexible Neural Electrode with Bioelectromechanical Compatibility and Brain Micromotion Detection

Donglei Chen iD, Yu Lu, Shuo Zhang, Wenqi Zhang, Zejie Yu, Shuideng Wang, Zhi Qu, Mingxing Cheng, Yiqing Yao, Deheng Wang, Zhan Yang, Lixin Dong iD

Advanced Healthcare Materials · 2026

DOI: 10.1002/adhm.202503101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von Donglei Chen und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China. Hauptthemen laut MEDLINE: Brain, Brain-Computer Interfaces, Electrodes, Implanted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Research Grants Council of the Hong Kong Special Administrative Region, City University of Hong Kong.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neural electrodes, as core components of brain‐computer interfaces(BCIs), face critical challenges in achieving stable mechanical coupling with brain tissue to ensure high‐quality signal acquisition. Current flexible electrodes, including semi‐invasive meningeal‐attached types and implantable cantilever designs, exhibit significant mechanical mismatches (elastic modulus 5–6 orders higher than brain tissue) due to material/structural limitations, leading to interfacial slippage. While thread‐like implants (e.g., Neuralink's electrodes) improve compliance via elongated structures, quantitative characterization of mechano‐bioelectric interactions remains unexplored. This study proposes a bioelectromechanical coupling strategy, emphasizing synchronized motion between the electrode and the brain tissue through exposed‐end deformation. A 4‐channel ultra‐flexible electrode (40 mm in length, 164 µm in width, and 3 µm in thickness) is optimized using finite‐element simulations and zero relative‐motion criteria, achieving an equivalent stiffness of 0.023 N m −1 —matching brain tissue micromotion stiffness. A nanorobotic manipulator installed inside a scanning electron microscope(SEM) with an atomic force microscope(AFM) cantilever enabled precision characterization under the simulated displacement of 25 µm, revealing interfacial forces of 575 nN and piezoresistive sensitivities of 6.4 pA mm −1 (length) and 10.2 pA µm −1 (displacement). The dual‐functionality (signal acquisition and micromotion sensing) electrodes demonstrate breakthrough potential, establishing quantitative design standards for next‐generation bioelectronic implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainBrain-Computer InterfacesElectrodes, ImplantedElectrodesHumansFinite Element AnalysisAnimals

Stichwörter der Autor:innen

bioelectromechanical compatibilitybrain micromotion detectionbrain‐computer interfaceneural electrode

Autor:innen und Institutionen

  • Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China.
  • Centre for Robotics and Automation, City University of Hong Kong Shenzhen Research Institute, Shenzhen, 518057, China.
  • School of Integrative Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215137, China.
  • Jiangsu Key Laboratory of Embodied Intelligence Robot Technology, Soochow University, Suzhou, 215137, China.

ORCID-Profile: Donglei Chen, Lixin Dong

Förderung

  • National Natural Science Foundation of China
  • Research Grants Council of the Hong Kong Special Administrative Region
  • City University of Hong Kong

Zitieren

APA

Chen, D., Lu, Y., Zhang, S., Zhang, W., Yu, Z., Wang, S., Qu, Z., Cheng, M., Yao, Y., Wang, D., Yang, Z., & Dong, L. (2026). An Ultra‐Flexible Neural Electrode with Bioelectromechanical Compatibility and Brain Micromotion Detection. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202503101

Vancouver

Chen D, Lu Y, Zhang S, Zhang W, Yu Z, Wang S, et al. An Ultra‐Flexible Neural Electrode with Bioelectromechanical Compatibility and Brain Micromotion Detection. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.202503101

BibTeX
@article{Chen2026,
  author = {Chen, Donglei and Lu, Yu and Zhang, Shuo and Zhang, Wenqi and Yu, Zejie and Wang, Shuideng and Qu, Zhi and Cheng, Mingxing and Yao, Yiqing and Wang, Deheng and Yang, Zhan and Dong, Lixin},
  title = {An Ultra‐Flexible Neural Electrode with Bioelectromechanical Compatibility and Brain Micromotion Detection},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  doi = {10.1002/adhm.202503101}
}
Kostenlos starten →