EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrochemical Biosensor for Rapid Detection of Acute Rejection in Kidney Transplants

Rohit Gupta iD, Nikolaos Salaris iD, Ashish Kalkal iD, Fernando Yuen Chang, Maryam Javed, Azhar Ali Khan, Priya Mandal iD, Stavroula Balabani iD, Reza Motallebzadeh iD, Manish K Tiwari iD

Advanced Healthcare Materials · 2026

DOI: 10.1002/adhm.202502831 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von Rohit Gupta und 9 weiteren Autor:innen. Beteiligte Einrichtung: Nanoengineered Systems Laboratory, UCL Mechanical Engineering, University College London, London, WC1E 7JE, UK. Hauptthemen laut MEDLINE: Biosensing Techniques, Kidney Transplantation, Graft Rejection, Electrochemical Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Rosetrees Trust, HORIZON EUROPE European Research Council, Royal Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kidney transplant recipients face a high risk of acute rejection (AR), where the immune system attacks the transplanted organ. Current diagnostics rely on invasive biopsies with procedural risks, costs, and limited temporal resolution. While urinary chemokines CXCL9 and CXCL10 are promising non‐invasive AR biomarkers, clinical adoption is limited by labor‐intensive detection and lack of point‐of‐care (POC) solutions. A rapid, label‐free electrochemical biosensing platform for simultaneous quantification of CXCL9 and CXCL10 chemokines from 5 µL of unprocessed urine in 15 min, which for ELISA and biopsy is between 24–72 hrs, is presented. The system uses screen‐printed carbon electrodes modified with a Ti 3 C 2 T x MXene‐crosslinked bovine serum albumin hydrogel, offering high conductivity, nano‐porosity, anti‐fouling properties, and signal stability for up to 30 days. The platform enables single‐digit pg/mL‐level sensitivity, meeting clinical thresholds. In a prospective clinical study, biosensor‐measured chemokine data trained a bootstrapped logistic regression classifier, achieving 83% AR classification accuracy. When combined with additional clinical and histopathological features, accuracy increased to 98%. This work integrates advanced materials, biosensor engineering, and machine learning to deliver a scalable, cost‐effective POC solution for real‐time, non‐invasive AR monitoring. The platform will help reduce biopsy dependence, enable earlier intervention, and ultimately improve long‐term transplant outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesKidney TransplantationGraft RejectionElectrochemical TechniquesChemokine CXCL9HumansBiomarkersHydrogelsChemokine CXCL10

Stichwörter der Autor:innen

acute rejectionantifoulingelectrochemical biosensorkidney disease monitoringpoint‐of‐care diagnostics

Substanzen

Chemokine CXCL9BiomarkersCXCL10 protein, humanCXCL9 protein, humanHydrogelsChemokine CXCL10

Autor:innen und Institutionen

  • Nanoengineered Systems Laboratory, UCL Mechanical Engineering, University College London, London, WC1E 7JE, UK.
  • UCL Hawkes Institute, University College London, London, W1W 7TS, UK.
  • Research Department of Surgical Biotechnology, Division of Surgery & Interventional Sciences, University College London, London, NW3 2PF, UK.
  • Department of Nephrology & Renal Transplantation, Royal Free Hospital London, London, NW3 2QG, UK.
  • FluME, UCL Mechanical Engineering, University College London, London, WC1E 7JE, UK.
  • Institute of Immunity & Transplantation, University College London, London, NW3 2PP, United Kingdom.

ORCID-Profile: Rohit Gupta, Nikolaos Salaris, Ashish Kalkal, Priya Mandal, Stavroula Balabani, Reza Motallebzadeh, Manish K Tiwari

Förderung

  • Rosetrees Trust
  • HORIZON EUROPE European Research Council
  • Royal Society
  • St Peter's Trust/The Royal Free Charity
  • Wellcome Trust
  • Wellcome / EPSRC Centre for Interventional and Surgical Sciences

Zitieren

APA

Gupta, R., Salaris, N., Kalkal, A., Chang, F. Y., Javed, M., Khan, A. A., Mandal, P., Balabani, S., Motallebzadeh, R., & Tiwari, M. K. (2026). Electrochemical Biosensor for Rapid Detection of Acute Rejection in Kidney Transplants. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202502831

Vancouver

Gupta R, Salaris N, Kalkal A, Chang FY, Javed M, Khan AA, et al. Electrochemical Biosensor for Rapid Detection of Acute Rejection in Kidney Transplants. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.202502831

BibTeX
@article{Gupta2026,
  author = {Gupta, Rohit and Salaris, Nikolaos and Kalkal, Ashish and Chang, Fernando Yuen and Javed, Maryam and Khan, Azhar Ali and Mandal, Priya and Balabani, Stavroula and Motallebzadeh, Reza and Tiwari, Manish K},
  title = {Electrochemical Biosensor for Rapid Detection of Acute Rejection in Kidney Transplants},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  doi = {10.1002/adhm.202502831}
}
Kostenlos starten →