EUVIMEDEUVIMED entdecken
Crossref

Forward Design of Single Ultra‐Wide Range and Highly Sensitive Flexible Pressure Sensor for Multi‐ Physiological‐Motion Monitoring

Jia Zhang iD, Xingyu Zhang, Xuyang An, Jiatai Chen, Shuai Wang, Xiaona Wang, PingAn Hu, Tiezhu Liu, Longqiu Li

Advanced Healthcare Materials · 2025-12 · 14 (31)

DOI: 10.1002/adhm.202501798 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 11.08.2025. Verfasst von Jia Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Microsystems and Microstructure Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Natural Science Foundation of Chongqing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Most human physiological and motion information can be converted into surface vibration signals, which can be monitored through flexible wearable pressure sensors. However, the pressure levels generated by different physiological signals vary widely, ranging from a few Pa to several MPa. The current existing flexible pressure sensors struggle to simultaneously achieve such a wide detection range with high sensitivity. To address this challenge, a forward design method is proposed to realize the ultra‐wide range and highly sensitive flexible pressure sensor simultaneous via the synergistic effects of the gradient porous structure, a multi‐level pyramid array, and a composite piezoresistive material. The sensitivity is calculated to be 345.8 (0–1 MPa) and 3320.2kPa −1 (1–2 MPa) after linear fitting. Impressively, the sensitivity increases with the increase of pressure, which is unusual as before. Additionally, the sensor exhibits a high resolution better than 1‰ across the full range, a fast response/recovery time (30/50 ms), and long‐term operational stability. Significantly, the sensor demonstrates the non‐saturating sensitivity characteristics, overcoming the bottleneck of saturation in flexible pressure sensors under high‐pressure conditions, thereby enabling high‐precision monitoring of physiological and motion signals across different pressure levels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesMonitoring, PhysiologicPressureHumansEquipment DesignMotionMovement

Stichwörter der Autor:innen

flexible pressure sensorforward designhighly sensitiveultra‐wide rangeunsaturated sensitivity

Autor:innen und Institutionen

  • Key Laboratory of Microsystems and Microstructure Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China.
  • College of Mathematical Medicine, Zhejiang Normal University, Jinhua, 321004, China.
  • Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Advanced Materials Division, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, 215123, China.

ORCID-Profile: Jia Zhang

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Chongqing
  • China Postdoctoral Science Foundation
  • Postdoctoral Fellowship Program of CPSF
  • Natural Science Foundation of Chongqing Municipality

Zitieren

APA

Zhang, J., Zhang, X., An, X., Chen, J., Wang, S., Wang, X., Hu, P., Liu, T., & Li, L. (2025). Forward Design of Single Ultra‐Wide Range and Highly Sensitive Flexible Pressure Sensor for Multi‐ Physiological‐Motion Monitoring. Advanced Healthcare Materials, 14(31). https://doi.org/10.1002/adhm.202501798

Vancouver

Zhang J, Zhang X, An X, Chen J, Wang S, Wang X, et al. Forward Design of Single Ultra‐Wide Range and Highly Sensitive Flexible Pressure Sensor for Multi‐ Physiological‐Motion Monitoring. Advanced Healthcare Materials. 2025;14(31). doi:10.1002/adhm.202501798

BibTeX
@article{Zhang2025,
  author = {Zhang, Jia and Zhang, Xingyu and An, Xuyang and Chen, Jiatai and Wang, Shuai and Wang, Xiaona and Hu, PingAn and Liu, Tiezhu and Li, Longqiu},
  title = {Forward Design of Single Ultra‐Wide Range and Highly Sensitive Flexible Pressure Sensor for Multi‐ Physiological‐Motion Monitoring},
  journal = {Advanced Healthcare Materials},
  year = {2025},
  volume = {14},
  number = {31},
  doi = {10.1002/adhm.202501798}
}
Kostenlos starten →