EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mandibular Implants: A Metamaterial‐Based Approach to Reducing Stress Shielding

Jorn-Ids Heins iD, Bram B J Merema iD, Joep Kraeima iD, Max J H Witjes iD, Anastasiia O Krushynska iD

Advanced Healthcare Materials · 2025

DOI: 10.1002/adhm.202500405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Jorn-Ids Heins und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, 9713 GZ, The Netherlands. Hauptthemen laut MEDLINE: Mandible. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biomechanical complications, such as stress shielding, bone resorption, and reconstruction failure, are prevalently associated with solid titanium mandible reconstruction plates. This study evaluates the potential of metamaterial designs with porous gyroid microarchitectures, to enhance biomechanical stimulation and mitigate these complications. A novel metamaterial reconstruction plate is compared with solid titanium plates, both patient‐specifically designed and fabricated from Ti6Al4 V alloy. Stress shielding is assessed through photoelasticity experiments and validated with finite element analysis (FEA). Transparent mandible models are loaded incrementally (0–1000 N) to analyze stress distributions in the implants, screws, and mandible segments. The metamaterial plate reduces stress concentrations in the distant mandibular regions from the defect, while increasing stress around the screws near the defect, favoring local mechanical stimulation. FEA confirms improved load distribution (p = 0.003). However, the metamaterial plate exhibited a lower load‐bearing capacity, failing at 775 N, while the solid plate withstood 1800 N without failure. Yet, the metamaterial design effectively reduced stress shielding, thereby enhancing biomechanical function near critical mandibular regions. Hence, despite their reduced load‐bearing capacity, they can, potentially, preserve bone integrity and prevent implant failure that should be validated in future (pre‐)clinical studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MandibleFinite Element AnalysisTitaniumHumansStress, MechanicalAlloysBone PlatesBiomechanical PhenomenaMaterials Testing

Stichwörter der Autor:innen

Metamaterialimplantmandiblephotoelasticityporous

Substanzen

Titaniumtitanium alloy (TiAl6V4)Alloys

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, 9713 GZ, The Netherlands.
  • 3D Lab, University Medical Center Groningen, University of Groningen, Groningen, 9713 GZ, The Netherlands.
  • Engineering and Technology Institute Groningen, University of Groningen, Groningen, 9747AG, The Netherlands.

ORCID-Profile: Jorn-Ids Heins, Bram B J Merema, Joep Kraeima, Max J H Witjes, Anastasiia O Krushynska

Zitieren

APA

Heins, J. I., Merema, B. B. J., Kraeima, J., Witjes, M. J. H., & Krushynska, A. O. (2025). Mandibular Implants: A Metamaterial‐Based Approach to Reducing Stress Shielding. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202500405

Vancouver

Heins JI, Merema BBJ, Kraeima J, Witjes MJH, Krushynska AO. Mandibular Implants: A Metamaterial‐Based Approach to Reducing Stress Shielding. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202500405

BibTeX
@article{Heins2025,
  author = {Heins, Jorn-Ids and Merema, Bram B J and Kraeima, Joep and Witjes, Max J H and Krushynska, Anastasiia O},
  title = {Mandibular Implants: A Metamaterial‐Based Approach to Reducing Stress Shielding},
  journal = {Advanced Healthcare Materials},
  year = {2025},
  doi = {10.1002/adhm.202500405}
}
Kostenlos starten →