Impact of Fiber Orientation in Electrospun PLA Scaffolds on Fluid Dynamics in a Custom Microfluidic Device
Advanced Healthcare Materials · 2025-09 · 14 (25)
DOI: 10.1002/adhm.202500378 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 17.06.2025. Verfasst von Elisa Capuana und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, University of Palermo, Palermo, 90128, Italy. Hauptthemen laut MEDLINE: Polyesters, Tissue Scaffolds, Lab-On-A-Chip Devices, Hydrodynamics. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero della Salute, MUR-PNRR project Ecosistema dell'Innovazione Sicilian MicronanoTech Research And Innovation Center (SAMOTHRACE).
Abstract (Originalsprache)
Organ‐on‐Chip (OoC) systems are evolving as vital tools in biomedical research, proposing advanced platforms to replicate human tissue microenvironments for drug testing and disease modeling. This study examines how the orientation of polylactic acid (PLA) fibers influences fluid movement in a custom OoC setup. PLA scaffolds are fabricated via electrospinning with either random or aligned fiber orientations. Scanning electron microscopy (SEM) reveals that random scaffolds are 70 µm thick with fibers measuring 1.12 µm, while aligned scaffolds are thinner at 35 µm with fibers of 1.02 µm. Porosity and matrix structure are analyzed to understand the impact of fiber arrangement. Liquid water permeability is tested using a custom three dimensional (3D)‐printed device conforming to ISO 7198:2016 standards. Computational fluid dynamics (CFD) simulations, employing the Porous Media Flow Module and Brinkman's equations, predict flow behavior based on scaffold morphology. A dual‐chamber microfluidic chip integrated with pressure sensors allows real‐time measurements to validate the simulations. Results demonstrate that fiber alignment significantly alters scaffold permeability and flow dynamics. These insights are valuable for tissue engineering, offering a validated framework to design microfluidic devices with tailored fluidic environments optimized for specific scaffold architectures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Engineering, University of Palermo, Palermo, 90128, Italy.
- Department of Biomedicina, Neuroscienze e Diagnostica avanzata (Bind), University of Palermo, Palermo, 90127, Italy.
ORCID-Profile: Francesco Lopresti
Förderung
- Ministero della Salute
- MUR-PNRR project Ecosistema dell'Innovazione Sicilian MicronanoTech Research And Innovation Center (SAMOTHRACE)
Zitieren
APA
Capuana, E., Testa, M., Marco, C. D., Lopresti, F., & La Carrubba, V. (2025). Impact of Fiber Orientation in Electrospun PLA Scaffolds on Fluid Dynamics in a Custom Microfluidic Device. Advanced Healthcare Materials, 14(25). https://doi.org/10.1002/adhm.202500378
Vancouver
Capuana E, Testa M, Marco CD, Lopresti F, La Carrubba V. Impact of Fiber Orientation in Electrospun PLA Scaffolds on Fluid Dynamics in a Custom Microfluidic Device. Advanced Healthcare Materials. 2025;14(25). doi:10.1002/adhm.202500378
BibTeX
@article{Capuana2025,
author = {Capuana, Elisa and Testa, Maria and Marco, Chiara Di and Lopresti, Francesco and La Carrubba, Vincenzo},
title = {Impact of Fiber Orientation in Electrospun PLA Scaffolds on Fluid Dynamics in a Custom Microfluidic Device},
journal = {Advanced Healthcare Materials},
year = {2025},
volume = {14},
number = {25},
doi = {10.1002/adhm.202500378}
}
EUVIMED