Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Heng Dong und 11 weiteren Autor:innen. Beteiligte Einrichtung: Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, No.30 Zhongyang Road, Nanjing, …. Hauptthemen laut MEDLINE: Saliva, Salivary Gland Neoplasms, Biosensing Techniques, Periodontitis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Key R&D Program of China, Nanjing Foundation for Development of Science and Technology, Nanjing Medical Science and Technique Development Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Saliva is a non‐invasive, easily collected fluid ideal for health monitoring, but its ultralow metabolite concentrations make accurate detection challenging for current analytical tools, limiting its clinical diagnostic use. Here, a homogeneous nanogrid film composed of Prussian blue/Au nanogrid (PB/AuNG) to fabricate salivary biosensors for diagnosing oral diseases is fabricated. The PB/AuNG nanogrid film allows for the uniform immobilization of oxidase enzymes or antibodies, thereby substantially enhancing the detection sensitivity for trace salivary biomarkers. Then it is designed biosensing chips modified with PB/AuNG to respectively detect the lactate (potential biomarkers of periodontitis) and interleukin (IL)‐6 (potential biomarkers of salivary gland tumor). The microchips have achieved the ultra‐low limit of 6.5 µM to lactate within 5 s and 0.14 fg mL −1 to IL‐6 within 20 min. After comprehensive performance evaluation and feasibility validation, a handheld saliva analyzer integrated with PB/AuNG‐based microchips for portable, non‐hospital‐based monitoring is developed. The device is subsequently employed to analyze real saliva samples from periodontitis and salivary gland tumor patients, successfully distinguishing between the two groups based on differences in lactate and IL‐6 concentrations. This study presents a diagnostic platform for early detection of saliva metabolites, aiming to promote proactive, personalized health management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaSalivary Gland NeoplasmsBiosensing TechniquesPeriodontitisHumansGoldInterleukin-6Lactic AcidMetal Nanoparticles

Stichwörter der Autor:innen

biosensing microchipnon‐invasive diagnosticsoral health monitoringsalivary biomarker

Substanzen

GoldInterleukin-6Lactic Acid

Autor:innen und Institutionen

  • Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, No.30 Zhongyang Road, Nanjing, 210008, China.
  • State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No.30 Puzhu Road, Nanjing, 211816, China.
  • Institute for Health Innovation & Technology, Biomedical Engineering Department, National University of Singapore, 21 Lower Kent Ridge Rd, Singapore, 119077, Singapore.

ORCID-Profile: Heng Dong, Qiang Li, Yu Zhang, Weijun Xiu, Yongbin Mou, Wanqin Jin

Förderung

  • National Key R&D Program of China
  • Nanjing Foundation for Development of Science and Technology
  • Nanjing Medical Science and Technique Development Foundation
  • Natural Science Foundation of Jiangsu Province
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Dong, H., Zhang, J., Liu, T., Li, X., Yuan, X., He, A., Li, Q., Zhang, Y., Xiu, W., Chu, Z., Mou, Y., & Jin, W. (2025). A Handheld Saliva Analyzer Employing Homogeneous Nanogrid Film for Noninvasive on‐Site Detection Periodontitis and Salivary Gland Tumor. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202404558

Vancouver

Dong H, Zhang J, Liu T, Li X, Yuan X, He A, et al. A Handheld Saliva Analyzer Employing Homogeneous Nanogrid Film for Noninvasive on‐Site Detection Periodontitis and Salivary Gland Tumor. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202404558

BibTeX
@article{Dong2025,
  author = {Dong, Heng and Zhang, Jing and Liu, Tao and Li, Xiaoye and Yuan, Xueli and He, Ao and Li, Qiang and Zhang, Yu and Xiu, Weijun and Chu, Zhenyu and Mou, Yongbin and Jin, Wanqin},
  title = {A Handheld Saliva Analyzer Employing Homogeneous Nanogrid Film for Noninvasive on‐Site Detection Periodontitis and Salivary Gland Tumor},
  journal = {Advanced Healthcare Materials},
  year = {2025},
  doi = {10.1002/adhm.202404558}
}
Kostenlos starten →