Prognosis of Cardiovascular Conditions Noninvasively Using Printable Elastomeric Electronic Skin
Advanced Healthcare Materials · 2025
DOI: 10.1002/adhm.202404056 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2025. Verfasst von Muthamil Selvan T und 1 weiteren Autor:innen. Beteiligte Einrichtung: Rubber Technology Centre, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India. Hauptthemen laut MEDLINE: Elastomers, Cardiovascular Diseases, Wearable Electronic Devices. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 91 Literaturangaben. Gefördert von: Science and Engineering Research Board.
Abstract (Originalsprache)
Lack of timely prognosis of cardiovascular condition (CVC) is resulting in increased mortality across the globe. Currently, available techniques are confined to medical facilities and need the intervention of specialists. Frequently, this impedes timely treatment, driven by socioeconomic factors. Consequently, the disease transcends toward incurable complications. In such a scenario, point‐of‐care diagnostic tools can help with prognosis at an early stage. Albeit there are such tools available, it is imperative to develop affordably in uncomplicated manufacturing techniques and should have simple readout and analysis modules for monitoring CVC. Accordingly, the solvent‐free manufacturing of stencil printable liquid elastomer‐carbon nanotube electronic skin‐based strain sensor, capable of accurately detecting pulse (at different positions) and other parameters like augmentation index and stiffness index of artery related to the CVC, is reported. The Poincare plot, derived from the recorded data, measures heart rate variability, a key indicator linked to mortality. Thanks to the staggering linearity, gauge factor of 234.26, fast response time of 85 ms (measured from pulse data), and cyclic stability (over 500 cycles), assist in the ease of detection of vital parameters. Furthermore, the sensor patch demonstrates its capability to acquire pulse waves under different real‐time artery conditions using cuff‐based pressure applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Rubber Technology Centre, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India.
ORCID-Profile: Titash Mondal
Förderung
- Science and Engineering Research Board
Zitieren
APA
Selvan T, M., & Mondal, T. (2025). Prognosis of Cardiovascular Conditions Noninvasively Using Printable Elastomeric Electronic Skin. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202404056
Vancouver
Selvan T M, Mondal T. Prognosis of Cardiovascular Conditions Noninvasively Using Printable Elastomeric Electronic Skin. Advanced Healthcare Materials. 2025. doi:10.1002/adhm.202404056
BibTeX
@article{SelvanT2025,
author = {Selvan T, Muthamil and Mondal, Titash},
title = {Prognosis of Cardiovascular Conditions Noninvasively Using Printable Elastomeric Electronic Skin},
journal = {Advanced Healthcare Materials},
year = {2025},
doi = {10.1002/adhm.202404056}
}
EUVIMED