Highly Sensitive Early Diagnosis of Kidney Damage Using Renal Clearable Zwitterion‐Coated Ferrite Nanoprobe via Magnetic Resonance Imaging In Vivo
Advanced Healthcare Materials · 2024
DOI: 10.1002/adhm.202304577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Ting Zhou und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Ferric Compounds, Kidney, Rats, Sprague-Dawley. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Tianjin Education Commission, Natural Science Foundation of Tianjin Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
Iron oxide nanoprobes exhibit substantial potential in magnetic resonance imaging (MRI) of kidney diseases and can eliminate the nephrotoxicity of gadolinium‐based contrast agents (GBCAs). Nevertheless, there is an extreme shortage of highly sensitive and renal clearable iron oxide nanoprobes suitable for early kidney damage detection through MRI. Herein, a renal clearable ultra‐small ferrite nanoprobe (UMFNPs@ZDS) is proposed for highly sensitive early diagnosis of kidney damage via structural and functional MRI in vivo for the first time. The nanoprobe comprises a ferrite core coated with a zwitterionic layer, and possesses a high T 1 relaxivity (12.52 m m −1 s −1 ), a small hydrodynamic size (6.43 nm), remarkable water solubility, excellent biocompatibility, and impressive renal clearable ability. In a rat model of unilateral ureteral obstruction (UUO), the nanoprobe‐based MRI can not only accurately visualize the locations of renal injury, but also provide comprehensive functional data including peak value, peak time, relative renal function (RRF), and clearance percentage via MRI. The findings prove the immense potential of ferrite nanoprobes as a superior alternative to GBCAs for the early diagnosis of kidney damage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China.
- Department of Radiology and Ultrasound, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China.
- Department of Rehabilitation, School of Medical Technology, Tianjin Medical University, Tianjin, 300203, China.
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical, University General Hospital, Tianjin, 300052, China.
ORCID-Profile: Shao-Kai Sun
Förderung
- Tianjin Education Commission
- Natural Science Foundation of Tianjin Municipality
- National Natural Science Foundation of China
Zitieren
APA
Zhou, T., Dong, Y., Wang, X., Liu, R., Cheng, R., Pan, J., Zhang, X., & Sun, S. K. (2024). Highly Sensitive Early Diagnosis of Kidney Damage Using Renal Clearable Zwitterion‐Coated Ferrite Nanoprobe via Magnetic Resonance Imaging In Vivo. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202304577
Vancouver
Zhou T, Dong Y, Wang X, Liu R, Cheng R, Pan J, et al. Highly Sensitive Early Diagnosis of Kidney Damage Using Renal Clearable Zwitterion‐Coated Ferrite Nanoprobe via Magnetic Resonance Imaging In Vivo. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202304577
BibTeX
@article{Zhou2024,
author = {Zhou, Ting and Dong, Yanzhi and Wang, Xiaoyi and Liu, Ruxia and Cheng, Ran and Pan, Jinbin and Zhang, Xuejun and Sun, Shao-Kai},
title = {Highly Sensitive Early Diagnosis of Kidney Damage Using Renal Clearable Zwitterion‐Coated Ferrite Nanoprobe via Magnetic Resonance Imaging In Vivo},
journal = {Advanced Healthcare Materials},
year = {2024},
doi = {10.1002/adhm.202304577}
}
EUVIMED