Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Luis Pinzon-Herrera und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ralph E. Martin Department of Chemical Engineering, University of Arkansas, 3202 Bell Engineering Center, Fayetteville, AR, 72701, USA. Hauptthemen laut MEDLINE: Schwann Cells, Extracellular Matrix, Collagen, Coated Materials, Biocompatible. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 73 Literaturangaben. Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, layer‐by‐layer coatings composed of heparin and collagen are proposed as an extracellular mimetic environment on nerve guide conduits (NGC) to modulate the behavior of Schwann cells (hSCs). The authors evaluated the stability, degradation over time, and bioactivity of six bilayers of heparin/collagen layer‐by‐layer coatings, denoted as (HEP/COL) 6 . The stability study reveals that (HEP/COL) 6 is stable after incubating the coatings in cell media for up to 21 days. The impact of (HEP/COL) 6 on hSCs viability, protein expression, and migration is evaluated. These assays show that hSCs cultured in (HEP/COL) 6 have enhanced protein expression and migration. This condition increases the expression of neurotrophic and immunomodulatory factors up to 1.5‐fold compared to controls, and hSCs migrated 1.34 times faster than in the uncoated surfaces. Finally, (HEP/COL) 6 is also applied to a commercial collagen‐based NGC, NeuraGen, and hSC viability and adhesion are studied after 6 days of culture. The morphology of NeuraGen is not altered by the presence of (HEP/COL) 6 and a nearly 170% increase of the cell viability is observed in the condition where NeuraGen is used with (HEP/COL) 6 . Additionally, cell adhesion on the coated samples is successfully demonstrated. This work demonstrates the reparative enhancing potential of extracellular mimetic coatings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Schwann CellsExtracellular MatrixCollagenCoated Materials, BiocompatibleHeparinAnimalsRatsCell SurvivalCell MovementSurface PropertiesCell AdhesionCells, CulturedNerve RegenerationGuided Tissue RegenerationTissue Scaffolds

Stichwörter der Autor:innen

NGCscollagenheparinhuman Schwann cellslayer‐by‐layertissue engineering

Substanzen

CollagenCoated Materials, BiocompatibleHeparin

Autor:innen und Institutionen

  • Ralph E. Martin Department of Chemical Engineering, University of Arkansas, 3202 Bell Engineering Center, Fayetteville, AR, 72701, USA.
  • Department of Chemical, Biochemical, and Environmental Engineering, University of Maryland Baltimore County, 1000 Hilltop Circle, Baltimore, MD, 21250, USA.
  • Science & Mathematics Division, Northwest Arkansas Community College, 1418 Burns Hall, Bentonville, AR, 72712, USA.

Förderung

  • National Science Foundation

Zitieren

APA

Pinzon-Herrera, L., Magness, J., Apodaca-Reyes, H., Sanchez, J., & Almodovar, J. (2024). Surface Modification of Nerve Guide Conduits with ECM Coatings and Investigating Their Impact on Schwann Cell Response. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202304103

Vancouver

Pinzon-Herrera L, Magness J, Apodaca-Reyes H, Sanchez J, Almodovar J. Surface Modification of Nerve Guide Conduits with ECM Coatings and Investigating Their Impact on Schwann Cell Response. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202304103

BibTeX
@article{PinzonHerrera2024,
  author = {Pinzon-Herrera, Luis and Magness, John and Apodaca-Reyes, Hector and Sanchez, Jesus and Almodovar, Jorge},
  title = {Surface Modification of Nerve Guide Conduits with ECM Coatings and Investigating Their Impact on Schwann Cell Response},
  journal = {Advanced Healthcare Materials},
  year = {2024},
  doi = {10.1002/adhm.202304103}
}
Kostenlos starten →