EUVIMEDEUVIMED entdecken
Crossref

An AIE Controlled “Off‐On” Cu 2+ ‐Sensitive Probe for Early Detection of Renal Fibrosis

Jie Zhou iD, Fusui Luo, Xiaomeng Dong, Huili Ma, Min Guan, Jin Zhang, Yiwen Sun, Junfen Feng

Advanced Healthcare Materials · 2024

DOI: 10.1002/adhm.202303944 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Jie Zhou und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China. Hauptthemen laut MEDLINE: Copper, Quantum Dots, Fibrosis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early detection of renal fibrosis (RF) is very important given that it is irreversible when it progresses to the terminal stage. A key marker of RF pathogenesis is activation of myomyofibroblasts, and its targeted imaging may be a promising approach for early detection of RF, but no study has directly imaged activation of renal myomyofibroblasts. Cu 2+ plays a major role in the fibrotic activity of myofibroblasts. Herein, inspired by that Cu 2+ can complex with bovine serum albumin (BSA), BSA‐Ag 2 S quantum dots (QDs) with aggregation‐induced emission (AIE) property are synthesized. Then BSA‐Ag 2 S QDs are modified by chitosan (CS) with renal targeting and hyaluronic acid (HA) with myofibroblast targeting to obtain the AIE assay system (QDs@CS@HA). The system is simple to synthesize, and produces a rapid NIR fluorescence signal turn‐on response and a low detection limit of 75 × 10 −9 m to Cu 2+ . In addition, cellular and animal experiments have shown that QDs@CS@HA has good biosafety and cell‐targeted imaging capability for RF. Based on the successful application of QDs@CS@HA and the mechanism of RF progression in early RF detection, it is expected that QDs@CS@HA may detect RF before the appearance of clinical symptoms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperQuantum DotsFibrosisAnimalsSerum Albumin, BovineChitosanHyaluronic AcidHumansKidneyKidney DiseasesMiceEarly DiagnosisCell Line

Stichwörter der Autor:innen

AIEQDsQDs@CS@HAearly detectionrenal fibrosis

Substanzen

CopperSerum Albumin, BovineChitosanHyaluronic Acid

Autor:innen und Institutionen

  • School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China.

ORCID-Profile: Jie Zhou

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhou, J., Luo, F., Dong, X., Ma, H., Guan, M., Zhang, J., Sun, Y., & Feng, J. (2024). An AIE Controlled “Off‐On” Cu 2+ ‐Sensitive Probe for Early Detection of Renal Fibrosis. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202303944

Vancouver

Zhou J, Luo F, Dong X, Ma H, Guan M, Zhang J, et al. An AIE Controlled “Off‐On” Cu 2+ ‐Sensitive Probe for Early Detection of Renal Fibrosis. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202303944

BibTeX
@article{Zhou2024,
  author = {Zhou, Jie and Luo, Fusui and Dong, Xiaomeng and Ma, Huili and Guan, Min and Zhang, Jin and Sun, Yiwen and Feng, Junfen},
  title = {An AIE Controlled “Off‐On” Cu 2+ ‐Sensitive Probe for Early Detection of Renal Fibrosis},
  journal = {Advanced Healthcare Materials},
  year = {2024},
  doi = {10.1002/adhm.202303944}
}
Kostenlos starten →