Single‐Response Duplexing of Electrochemical Label‐Free Biosensor from the Same Tag
Advanced Healthcare Materials · 2024
DOI: 10.1002/adhm.202303509 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Juliana N Y Costa und 15 weiteren Autor:innen. Beteiligte Einrichtung: Brazilian Nanotechnology National Laboratory, Brazilian Center for Research in Energy and Materials, Campinas, São Paulo, 13083-970, Brazil. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 105 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: São Paulo Research Foundation, Brazilian Coordination for Improvement of Higher Education Personnel, Brazilian National Council for Scientific and Technological Development.
Abstract (Originalsprache)
Multiplexing is a valuable strategy to boost throughput and improve clinical accuracy. Exploiting the vertical, meshed design of reproducible and low‐cost ultra‐dense electrochemical chips, the unprecedented single‐response multiplexing of typical label‐free biosensors is reported. Using a cheap, handheld one‐channel workstation and a single redox probe, that is, ferro/ferricyanide, the recognition events taking place on two spatially resolved locations of the same working electrode can be tracked along a single voltammetry scan by collecting the electrochemical signatures of the probe in relation to different quasi‐reference electrodes, Au (0 V) and Ag/AgCl ink (+0.2 V). This spatial isolation prevents crosstalk between the redox tags and interferences over functionalization and binding steps, representing an advantage over the existing non‐spatially resolved single‐response multiplex strategies. As proof of concept, peptide‐tethered immunosensors are demonstrated to provide the duplex detection of COVID‐19 antibodies, thereby doubling the throughput while achieving 100% accuracy in serum samples. The approach is envisioned to enable broad applications in high‐throughput and multi‐analyte platforms, as it can be tailored to other biosensing devices and formats.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Brazilian Nanotechnology National Laboratory, Brazilian Center for Research in Energy and Materials, Campinas, São Paulo, 13083-970, Brazil.
- Center for Natural and Human Sciences, Federal University of ABC, Santo André, São Paulo, 09210-580, Brazil.
- Institute of Chemistry, University of Campinas, Campinas, São Paulo, 13083-970, Brazil.
- Research Center for Materials, Architectures and Integration of Nanomembranes (MAIN), Chemnitz University of Technology, 09126, Chemnitz, Germany.
- Department of Chemistry, Clemson University, Clemson, SC, 29634, USA.
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, 13565-590, Brazil.
ORCID-Profile: Leandro Merces, Renato S Lima
Förderung
- São Paulo Research Foundation
- Brazilian Coordination for Improvement of Higher Education Personnel
- Brazilian National Council for Scientific and Technological Development
- Fundação de Amparo à Pesquisa do Estado de São Paulo
Zitieren
APA
Costa, J. N. Y., Pimentel, G. J. C., Poker, J. A., Merces, L., Paschoalino, W. J., Vieira, L. C. S., Castro, A. C. H., Alves, W. A., Ayres, L. B., Kubota, L. T., Santhiago, M., Garcia, C. D., Piazzetta, M. H. O., Gobbi, A. L., Shimizu, F. M., & Lima, R. S. (2024). Single‐Response Duplexing of Electrochemical Label‐Free Biosensor from the Same Tag. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202303509
Vancouver
Costa JNY, Pimentel GJC, Poker JA, Merces L, Paschoalino WJ, Vieira LCS, et al. Single‐Response Duplexing of Electrochemical Label‐Free Biosensor from the Same Tag. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202303509
BibTeX
@article{Costa2024,
author = {Costa, Juliana N Y and Pimentel, Gabriel J C and Poker, Júlia A and Merces, Leandro and Paschoalino, Waldemir J and Vieira, Luis C S and Castro, Ana C H and Alves, Wendel A and Ayres, Lucas B and Kubota, Lauro T and Santhiago, Murilo and Garcia, Carlos D and Piazzetta, Maria H O and Gobbi, Angelo L and Shimizu, Flávio M and Lima, Renato S},
title = {Single‐Response Duplexing of Electrochemical Label‐Free Biosensor from the Same Tag},
journal = {Advanced Healthcare Materials},
year = {2024},
doi = {10.1002/adhm.202303509}
}
EUVIMED