EUVIMEDEUVIMED entdecken
Crossref

Magnetic Resonance Angiography with Hour‐Scale Duration after Single Low‐Dose Administration of Biocompatible Gadolinium Oxide Nanoprobe

Jiaojiao Wang, Bing Han, Min Ma, Yujie Zhao, Bingjie Li, Junzi Zhou, Chao Wu, Xuening Zhang, Jinbin Pan, Shao-Kai Sun iD

Advanced Healthcare Materials · 2024-04 · 13 (9)

DOI: 10.1002/adhm.202303389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 02.01.2024. Verfasst von Jiaojiao Wang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Contrast Media. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Tianjin Health Research Project, Tianjin Key Medical Discipline (Specialty) Construction Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Long‐term contrast‐enhanced angiography offers significant advantages in theranostics for diverse vascular diseases, particularly in terms of real‐time dynamic monitoring during acute vascular events; However, achieving vascular imaging with a duration of hours through a single administration of low‐dose contrast agent remains challenging. Herein, a hyaluronic acid‐templated gadolinium oxide (HA@Gd 2 O 3 ) nanoprobe‐enhanced magnetic resonance angiography (MRA) is proposed to address this bottleneck issue for the first time. The HA@Gd 2 O 3 nanoprobe synthesized from a facile one‐pot biomineralization method owns ultrasmall size, good biocompatibility, optimal circulation half‐life (≈149 min), and a relatively high T 1 relaxivity ( r 1 ) under both clinical 3 T (8.215 mM −1 s −1 ) and preclinical 9.4 T (4.023 mM −1 s −1 ) equipment. The HA@Gd 2 O 3 nanoprobe‐enhanced MRA highlights major vessels readily with significantly improved contrast, extended imaging duration for at least 2 h, and ultrahigh resolution of 0.15 mm under 9.4 T, while only requiring half clinical dosage of Gd. This technique can enable rapid diagnosis and real‐time dynamic monitoring of vascular changes in a model of acute superior mesenteric vein thrombosis with only a single injection of nanoprobe. The HA@Gd 2 O 3 nanoprobe‐enhanced MRA provides a sophisticated approach for long‐term (hour scale) vascular imaging with ultrahigh resolution and high contrast through single administration of low‐dose contrast agent.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyContrast MediaMagnetic Resonance ImagingGadolinium

Stichwörter der Autor:innen

MRAbiocompatibilitydynamic monitoringgadolinium oxidehyaluronic acidnanoprobe

Substanzen

Contrast Mediagadolinium oxideGadolinium

Autor:innen und Institutionen

  • Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China.
  • Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China.
  • School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China.

ORCID-Profile: Shao-Kai Sun

Förderung

  • National Natural Science Foundation of China
  • Tianjin Health Research Project
  • Tianjin Key Medical Discipline (Specialty) Construction Project
  • Science & Technology Development Fund of Tianjin Education Commission for Higher Education
  • the Natural Science Foundation of Tianjin City
  • Tianjin Medical University "Clinical Talent Training 123 Climbing Plan"

Zitieren

APA

Wang, J., Han, B., Ma, M., Zhao, Y., Li, B., Zhou, J., Wu, C., Zhang, X., Pan, J., & Sun, S. K. (2024). Magnetic Resonance Angiography with Hour‐Scale Duration after Single Low‐Dose Administration of Biocompatible Gadolinium Oxide Nanoprobe. Advanced Healthcare Materials, 13(9). https://doi.org/10.1002/adhm.202303389

Vancouver

Wang J, Han B, Ma M, Zhao Y, Li B, Zhou J, et al. Magnetic Resonance Angiography with Hour‐Scale Duration after Single Low‐Dose Administration of Biocompatible Gadolinium Oxide Nanoprobe. Advanced Healthcare Materials. 2024;13(9). doi:10.1002/adhm.202303389

BibTeX
@article{Wang2024,
  author = {Wang, Jiaojiao and Han, Bing and Ma, Min and Zhao, Yujie and Li, Bingjie and Zhou, Junzi and Wu, Chao and Zhang, Xuening and Pan, Jinbin and Sun, Shao-Kai},
  title = {Magnetic Resonance Angiography with Hour‐Scale Duration after Single Low‐Dose Administration of Biocompatible Gadolinium Oxide Nanoprobe},
  journal = {Advanced Healthcare Materials},
  year = {2024},
  volume = {13},
  number = {9},
  doi = {10.1002/adhm.202303389}
}
Kostenlos starten →