Releasable, Immune‐Instructive, Bioinspired Multilayer Coating Resists Implant‐Induced Fibrosis while Accelerating Tissue Repair
Advanced Healthcare Materials · 2024
DOI: 10.1002/adhm.202302611 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2024. Verfasst von Riki Toita und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-8-31 Midorigaoka, Ikeda, Osaka, 563-8577, J…. Hauptthemen laut MEDLINE: Prostheses and Implants, Biocompatible Materials. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Niterra Co., Ltd..
Abstract (Originalsprache)
Implantable biomaterials trigger foreign body reactions (FBRs), which reduces the functional life of medical devices and prevents effective tissue regeneration. Although existing therapeutic approaches can circumvent collagen‐rich fibrotic encapsulation secondary to FBRs, they disrupt native tissue repair. Herein, a new surface engineering strategy in which an apoptotic‐mimetic, immunomodulatory, phosphatidylserine liposome (PSL) is released from an implant coating to induce the formation of a macrophage phenotype that mitigates FBRs and improves tissue healing is described. PSL‐multilayers constructed on implant surfaces via the layer‐by‐layer method release PSLs over a 1‐month period. In rat muscles, poly(etheretherketone) (PEEK), a nondegradable polymer implant model, induces FBRs with dense fibrotic scarring under an aberrant cellular profile that recruits high levels of inflammatory infiltrates, foreign body giant cells (FBGCs), scar‐forming myofibroblasts, and inflammatory M1‐like macrophages but negligible amounts of anti‐inflammatory M2‐like phenotypes. However, the PSL‐multilayer coating markedly diminishes these detrimental signatures by shifting the macrophage phenotype. Unlike other therapeutics, PSL‐multilayered coatings also stimulate muscle regeneration. This study demonstrates that PSL‐multilayered coatings are effective in eliminating FBRs and promoting regeneration, hence offering potent and broad applications for implantable biomaterials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-8-31 Midorigaoka, Ikeda, Osaka, 563-8577, Japan.
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan.
- Niterra Co., Ltd., 2808 Iwasaki, Komaki, Aichi, 485-8510, Japan.
- NGK Spark Plug-AIST Healthcare Materials Cooperative Research Laboratory, 2266-98 Anagahora, Shimoshidami, Moriyama-ku, Nagoya, Aichi, 463-8560, Japan.
- Department of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
- Division of Biopharmaceutics and Pharmacokinetics, National Cerebral and Cardiovascular Center Research Institute, 6-1 Shinmachi, Kishibe, Suita, Osaka, 564-8565, Japan.
ORCID-Profile: Riki Toita, Akira Tsuchiya, Jeong-Hun Kang
Förderung
- Japan Society for the Promotion of Science
- Niterra Co., Ltd.
Zitieren
APA
Toita, R., Kitamura, M., Tsuchiya, A., Kang, J. H., & Kasahara, S. (2024). Releasable, Immune‐Instructive, Bioinspired Multilayer Coating Resists Implant‐Induced Fibrosis while Accelerating Tissue Repair. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202302611
Vancouver
Toita R, Kitamura M, Tsuchiya A, Kang JH, Kasahara S. Releasable, Immune‐Instructive, Bioinspired Multilayer Coating Resists Implant‐Induced Fibrosis while Accelerating Tissue Repair. Advanced Healthcare Materials. 2024. doi:10.1002/adhm.202302611
BibTeX
@article{Toita2024,
author = {Toita, Riki and Kitamura, Masahiro and Tsuchiya, Akira and Kang, Jeong-Hun and Kasahara, Shinjiro},
title = {Releasable, Immune‐Instructive, Bioinspired Multilayer Coating Resists Implant‐Induced Fibrosis while Accelerating Tissue Repair},
journal = {Advanced Healthcare Materials},
year = {2024},
doi = {10.1002/adhm.202302611}
}
EUVIMED