Near Infrared Emissive Lanthanide Luminescence Nanoparticle Used in Early Diagnosis and Brain Temperature Detection for Ischemic Stroke
Advanced Healthcare Materials · 2023
DOI: 10.1002/adhm.202302276 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2023. Verfasst von Shen-Jie Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Stroke Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 ZhiZaoJu Road, Huangp…. Hauptthemen laut MEDLINE: Ischemic Stroke, Lanthanoid Series Elements, Stroke, Nanoparticles. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Natural Science and Foundation of China, Shanghai Municipal Science and Technology Commission, Shanghai Pujiang Program.
Themen: Schlaganfall
Abstract (Originalsprache)
Ischemic stroke (IS) is one of the most dangerous medical conditions resulting in high mortality and morbidity. The increased brain temperature after IS is closely related to prognosis, making it highly significant for the early diagnosis and the progression evaluation of IS. Herein, a temperature‐responsive near infrared (NIR) emissive lanthanide luminescence nanoparticle is developed for the early diagnosis and brain temperature detection of IS. After intravenous injection, the nanoparticles can pass through the damaged blood–brain barrier of the ischemic region, allowing the extravasation and enrichment of nanoparticles into the ischemic brain tissue. The NIR luminescence signals of the nanoparticles are used not only to judge the location and severity of the cerebral ischemic injury but also to report the brain temperature variation in the ischemic area through a visualized way. The results show that the designed nanoparticles can be used for the early diagnosis of ischemic stroke and minimally invasive temperature detection of cerebral ischemic tissues in transient middle cerebral artery occlusion mice model, which is expected to make the clinical diagnosis of ischemic stroke more rapid and convenient, more accurately evaluate the state of brain injury in stroke patients and also guide stroke hypothermia treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurology, Stroke Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 ZhiZaoJu Road, Huangpu District, Shanghai, 200011, China.
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, China.
ORCID-Profile: Xingjun Zhu
Förderung
- National Natural Science and Foundation of China
- Shanghai Municipal Science and Technology Commission
- Shanghai Pujiang Program
- ShanghaiTech University, Crossover Research Fund Project from Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine
- Research Discipline Fund of the Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine
- the 200 Talent project from Shanghai Municipal Education Commission-Gaofeng Clinical Medicine Grant Support
- Science and Technology Commission of Shanghai Municipality
Zitieren
APA
Li, S. J., Li, F., Kong, N., Liu, J. R., & Zhu, X. (2023). Near Infrared Emissive Lanthanide Luminescence Nanoparticle Used in Early Diagnosis and Brain Temperature Detection for Ischemic Stroke. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202302276
Vancouver
Li SJ, Li F, Kong N, Liu JR, Zhu X. Near Infrared Emissive Lanthanide Luminescence Nanoparticle Used in Early Diagnosis and Brain Temperature Detection for Ischemic Stroke. Advanced Healthcare Materials. 2023. doi:10.1002/adhm.202302276
BibTeX
@article{Li2023,
author = {Li, Shen-Jie and Li, Fang and Kong, Na and Liu, Jian-Ren and Zhu, Xingjun},
title = {Near Infrared Emissive Lanthanide Luminescence Nanoparticle Used in Early Diagnosis and Brain Temperature Detection for Ischemic Stroke},
journal = {Advanced Healthcare Materials},
year = {2023},
doi = {10.1002/adhm.202302276}
}
EUVIMED