EUVIMEDEUVIMED entdecken
Crossref

Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor

Yi Huang, Lingyu Zhao, Minkun Cai, Jiaqi Zhu, Liu Wang, Xinxing Chen, Yumin Zeng, Liqing Zhang, Jidong Shi, Chuan Fei Guo iD

Advanced Healthcare Materials · 2023-11 · 12 (29)

DOI: 10.1002/adhm.202301838 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 31.08.2023. Verfasst von Yi Huang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Southern University of Science and Technology Hospital (SUSTech-Hospital), Shenzhen, 518071, China. Hauptthemen laut MEDLINE: Arteriosclerosis, Cardiovascular Diseases, Wearable Electronic Devices. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Scientific Research Program of Shenzhen Nanshan District, Special Foundation of The President of SUSTech Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Arteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is often evaluated by clinically measuring the pulse wave velocity (PWV) using a two‐point approach that requires bulky medical equipment and a skilled operator. Although wearable photoplethysmographic sensors for PWV monitoring are developed in recent years, likewise, this technique is often based on two‐point measurement, and the signal can easily be interfered with by natural light. Herein, a single‐point strategy is reported based on stable fingertip pulse monitoring using a flexible iontronic pressure sensor for heart‐fingertip PWV (hfPWV) measurement. The iontronic sensor exhibits a high pressure‐resolution on the order of 0.1 Pa over a wide linearity range, allowing the capture of characteristic peaks of fingertip pulse waves. The forward and reflected waves of the pulse are extracted and the time difference between the two waves is computed for hfPWV measurement using Hiroshi's method. Furthermore, a hfPWV‐based model is established for arteriosclerosis evaluation with an accuracy comparable to that of existing clinical criteria, and the validity of the model is verified clinically. The work provides a reliable technique that can be used in wearable arteriosclerosis assessment systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArteriosclerosisCardiovascular DiseasesWearable Electronic DevicesHumansPulse Wave AnalysisMonitoring, Physiologic

Stichwörter der Autor:innen

arteriosclerosisfingertip pulsesflexible pressure sensorsiontronic nanointerfacespulse wave velocity

Autor:innen und Institutionen

  • Department of Cardiology, Southern University of Science and Technology Hospital (SUSTech-Hospital), Shenzhen, 518071, China.
  • Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China.
  • CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230026, China.
  • Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Southern University of Science and Technolog…
  • Department of Sports Center, Southern University of Science and Technology, Shenzhen, 518055, China.
  • Department of Endocrinology, Southern University of Science and Technology Hospital (SUSTech-hospital), Shenzhen, 518071, China.

ORCID-Profile: Chuan Fei Guo

Förderung

  • National Natural Science Foundation of China
  • Scientific Research Program of Shenzhen Nanshan District
  • Special Foundation of The President of SUSTech Hospital
  • Natural Science Foundation of Guangdong Province

Zitieren

APA

Huang, Y., Zhao, L., Cai, M., Zhu, J., Wang, L., Chen, X., Zeng, Y., Zhang, L., Shi, J., & Guo, C. F. (2023). Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor. Advanced Healthcare Materials, 12(29). https://doi.org/10.1002/adhm.202301838

Vancouver

Huang Y, Zhao L, Cai M, Zhu J, Wang L, Chen X, et al. Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor. Advanced Healthcare Materials. 2023;12(29). doi:10.1002/adhm.202301838

BibTeX
@article{Huang2023,
  author = {Huang, Yi and Zhao, Lingyu and Cai, Minkun and Zhu, Jiaqi and Wang, Liu and Chen, Xinxing and Zeng, Yumin and Zhang, Liqing and Shi, Jidong and Guo, Chuan Fei},
  title = {Arteriosclerosis Assessment Based on Single‐Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor},
  journal = {Advanced Healthcare Materials},
  year = {2023},
  volume = {12},
  number = {29},
  doi = {10.1002/adhm.202301838}
}
Kostenlos starten →