EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Breaking a Dogma: High‐Throughput Live‐Cell Imaging in Real‐Time with Hoechst 33342

Heiko Fuchs iD, Kirsten Jahn, Xiaonan Hu, Roland Meister, Maximilian Binter, Carsten Framme

Advanced Healthcare Materials · 2023

DOI: 10.1002/adhm.202300230 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2023. Verfasst von Heiko Fuchs und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Ophthalmology, University Eye Hospital, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany. Hauptthemen laut MEDLINE: Benzimidazoles, Cell Nucleus. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automated high‐throughput live cell imaging (LCI) enables investigation of substance effects on cells in vitro. Usually, cell number is analyzed by phase‐contrast imaging, which is reliable only for a few cell types. Therefore, an accurate cell counting method, such as staining the nuclei with Hoechst 33342 before LCI, will be desirable. However, since the mid‐1980s, the dogma exists that Hoechst can only be used for endpoint analyses because of its cytotoxic properties and the potentially phototoxic effects of the excitation light. Since microscopic camera sensitivity has significantly improved, this study investigates whether this dogma is still justified. Therefore, exposure parameters are optimized using a 4× objective, and the minimum required Hoechst concentration is evaluated, allowing LCI at 30‐min intervals over 5 days. Remarkably, a Hoechst concentration of only 57 × 10 −9 m significantly inhibits proliferation and thus impairs cell viability. However, Hoechst concentrations between 7 × 10 −9 and 28 × 10 −9 m can be determined, which are neither cytotoxic nor impacting cell viability, proliferation, or signaling pathways. The method can be adapted to regular inverted fluorescence microscopes and allows, for example, to determine the cytotoxicity of a substance or the transduction efficiency, with the advantage that the analysis can be repeated at any desired time point.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BenzimidazolesCell NucleusMicroscopy, FluorescenceFluorescent Dyes

Stichwörter der Autor:innen

Hoechst 33342fluorescent microscopyhigh-throughput analysisreal-time live-cell imaging

Substanzen

bisbenzimide ethoxide trihydrochlorideBenzimidazolesFluorescent Dyes

Autor:innen und Institutionen

  • Institute of Ophthalmology, University Eye Hospital, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany.
  • Department of Psychiatry, Social Psychiatry and Psychotherapy, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover, Germany.

ORCID-Profile: Heiko Fuchs

Zitieren

APA

Fuchs, H., Jahn, K., Hu, X., Meister, R., Binter, M., & Framme, C. (2023). Breaking a Dogma: High‐Throughput Live‐Cell Imaging in Real‐Time with Hoechst 33342. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202300230

Vancouver

Fuchs H, Jahn K, Hu X, Meister R, Binter M, Framme C. Breaking a Dogma: High‐Throughput Live‐Cell Imaging in Real‐Time with Hoechst 33342. Advanced Healthcare Materials. 2023. doi:10.1002/adhm.202300230

BibTeX
@article{Fuchs2023,
  author = {Fuchs, Heiko and Jahn, Kirsten and Hu, Xiaonan and Meister, Roland and Binter, Maximilian and Framme, Carsten},
  title = {Breaking a Dogma: High‐Throughput Live‐Cell Imaging in Real‐Time with Hoechst 33342},
  journal = {Advanced Healthcare Materials},
  year = {2023},
  doi = {10.1002/adhm.202300230}
}
Kostenlos starten →