Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 30.03.2023. Verfasst von Sebastian Roubert Martinez und 3 weiteren Autor:innen. Beteiligte Einrichtung: John A. Paulson School of Engineering and Applied Sciences, Harvard University, 150 Western Avenue, Boston, MA, 02134, USA. Hauptthemen laut MEDLINE: Hydrogels, Polymers. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 80 Literaturangaben. Gefördert von: Harvard School of Engineering and Applied Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cutaneous electrodes are routinely used for noninvasive electrophysiological sensing of signals from the brain, the heart, and the neuromuscular system. These bioelectronic signals propagate as ionic charge from their sources to the skin–electrode interface where they are then sensed as electronic charge by the instrumentation. However, these signals suffer from low signal‐to‐noise ratio arising from the high impedance at the tissue‐to‐electrode contact interface. This paper reports that soft conductive polymer hydrogels made purely of poly(3,4‐ethylenedioxy‐thiophene) doped with poly(styrene sulfonate) present nearly an order of magnitude decrease in the skin–electrode contact impedance (88%, 82%, and 77% at 10, 100, and 1 kHz, respectively) when compared to clinical electrodes in an ex vivo model that isolates the bioelectrochemical features of a single skin–electrode contact. Integrating these pure soft conductive polymer blocks into an adhesive wearable sensor enables high fidelity bioelectronic signals with higher signal‐to‐noise ratio (average 2.1 dB increase, max 3.4 dB increase) when compared to clinical electrodes across all subjects. The utility of these electrodes is demonstrated in a neural interface application. The conductive polymer hydrogels enable electromyogram‐based velocity control of a robotic arm to complete a pick and place task. This work provides a basis for the characterization and use of conductive polymer hydrogels to better couple human and machine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrogelsPolymersHumansElectric ImpedanceElectrodesSkin

Stichwörter der Autor:innen

bioelectronicsconductive polymershydrogelsneural interfacesskin

Substanzen

HydrogelsPolymers

Autor:innen und Institutionen

  • John A. Paulson School of Engineering and Applied Sciences, Harvard University, 150 Western Avenue, Boston, MA, 02134, USA.

ORCID-Profile: Sebastian Roubert Martinez, Paul Le Floch, Robert D Howe

Förderung

  • Harvard School of Engineering and Applied Sciences

Zitieren

APA

Roubert Martinez, S., Le Floch, P., Liu, J., & Howe, R. D. (2023). Pure Conducting Polymer Hydrogels Increase Signal‐to‐Noise of Cutaneous Electrodes by Lowering Skin Interface Impedance. Advanced Healthcare Materials, 12(17). https://doi.org/10.1002/adhm.202202661

Vancouver

Roubert Martinez S, Le Floch P, Liu J, Howe RD. Pure Conducting Polymer Hydrogels Increase Signal‐to‐Noise of Cutaneous Electrodes by Lowering Skin Interface Impedance. Advanced Healthcare Materials. 2023;12(17). doi:10.1002/adhm.202202661

BibTeX
@article{RoubertMartinez2023,
  author = {Roubert Martinez, Sebastian and Le Floch, Paul and Liu, Jia and Howe, Robert D},
  title = {Pure Conducting Polymer Hydrogels Increase Signal‐to‐Noise of Cutaneous Electrodes by Lowering Skin Interface Impedance},
  journal = {Advanced Healthcare Materials},
  year = {2023},
  volume = {12},
  number = {17},
  doi = {10.1002/adhm.202202661}
}
Kostenlos starten →