EUVIMEDEUVIMED entdecken
Crossref

Pixel‐Level X‐Ray to NIR Image Fusion Based on Lead‐Free Halide Perovskite for Biological Imaging

Wei Tian, Hairui Zhang, Xinyi Qian, Zhenyu Ji, Fei Wang, Zhentao Du, Xue Zhao, Bingsuo Zou, Hui Peng

Advanced Functional Materials · 2026-05 · 36 (42)

DOI: 10.1002/adfm.75002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 18.03.2026. Verfasst von Wei Tian und 8 weiteren Autor:innen. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Guangxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Combining information from different images for multispectral image fusion can enhance human or machine perception. Nowadays, various luminescent materials with different spectral responses are used for image fusion, but this requires complex algorithms and systems to address pixel and position mismatches. Using a single luminescent material to obtain multispectral imaging can effectively avoid pixel mismatch and complex imaging processing. Herein, we report efficient blue‐light‐excitable ultrabroadband white emission and near‐infrared (NIR) emission in the Te 4+ /Mo 4+ ‐codoped Cs 2 ZrCl 6 with a luminous efficiency of 94.2% (NIR region: 52.6%). Moreover, this compound also shows bright radioluminescence with a light yield of 55 000 photons/MeV in the visible light region. Benefiting from these fascinating optical properties, high‐performance single‐component white light‐emitting diode (WLED), NIR LED, and X‐ray scintillator were fabricated based on Te 4+ /Mo 4+ ‐codoped Cs 2 ZrCl 6 /polydimethylsiloxane flexible film. Particularly, we took bullfrog palm as the target object, and demonstrated its applications in white light imaging, NIR imaging, and X‐ray imaging, respectively. Without pixel mismatch and complicated imaging processing, the pixel‐level X‐ray to NIR image fusion was realized, which can not only observe the wound of bullfrog palm, but also clearly obtain the structure and distribution of blood vessels and skeleton textures under the skin tissue of bullfrog palm.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Guangxi Province

Zitieren

APA

Tian, W., Zhang, H., Qian, X., Ji, Z., Wang, F., Du, Z., Zhao, X., Zou, B., & Peng, H. (2026). Pixel‐Level X‐Ray to NIR Image Fusion Based on Lead‐Free Halide Perovskite for Biological Imaging. Advanced Functional Materials, 36(42). https://doi.org/10.1002/adfm.75002

Vancouver

Tian W, Zhang H, Qian X, Ji Z, Wang F, Du Z, et al. Pixel‐Level X‐Ray to NIR Image Fusion Based on Lead‐Free Halide Perovskite for Biological Imaging. Advanced Functional Materials. 2026;36(42). doi:10.1002/adfm.75002

BibTeX
@article{Tian2026,
  author = {Tian, Wei and Zhang, Hairui and Qian, Xinyi and Ji, Zhenyu and Wang, Fei and Du, Zhentao and Zhao, Xue and Zou, Bingsuo and Peng, Hui},
  title = {Pixel‐Level X‐Ray to NIR Image Fusion Based on Lead‐Free Halide Perovskite for Biological Imaging},
  journal = {Advanced Functional Materials},
  year = {2026},
  volume = {36},
  number = {42},
  doi = {10.1002/adfm.75002}
}
Kostenlos starten →