EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensing of Chloride Ions in Sweat by Means of Printed Extended‐Gate Organic Electrochemical Transistors

Cristiano Bortolotti, Andrea Ottomaniello, Paola Parlanti, Virgilio Mattoli, Dario Natali, Andrea Aliverti, Adrica Kyndiah, Mario Caironi

Advanced Functional Materials · 2026-01 · 36 (5)

DOI: 10.1002/adfm.202511675 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 08.08.2025. Verfasst von Cristiano Bortolotti und 7 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE European Innovation Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accurate monitoring of chloride levels in sweat is crucial for diagnosing and managing cystic fibrosis (CF). The standard clinical approach is limited by the need for centralized, expensive, and labor‐intensive processes. To overcome such limits, cost‐effective wearable technologies allowing continuous monitoring are desirable. Toward such a goal, this study introduces a sensing platform based on inkjet‐printed extended‐gate organic electrochemical transistors (ExG‐OECTs) for the accurate quantification of chloride ions in sweat. The optimized ExG‐OECT achieves very good electrical performance, characterized by a high normalized transconductance, an on/off ratio >10 5 , and excellent stability during prolonged operation. An Ag/AgCl electrode fabricated via chemical oxidation of an inkjet‐printed Ag electrode is employed as a sensing element and demonstrates remarkable sensitivity and selectivity for chloride ions both in simple chloride solutions and in artificial eccrine perspiration. The developed ExG‐OECT sensor demonstrates consistent and robust chloride ion detection across the physiological range, highlighting its significant potential as a powerful tool for non‐invasive, real‐time sweat analysis in wearable health monitoring technologies.

Förderung

  • HORIZON EUROPE European Innovation Council

Zitieren

APA

Bortolotti, C., Ottomaniello, A., Parlanti, P., Mattoli, V., Natali, D., Aliverti, A., Kyndiah, A., & Caironi, M. (2026). Sensing of Chloride Ions in Sweat by Means of Printed Extended‐Gate Organic Electrochemical Transistors. Advanced Functional Materials, 36(5). https://doi.org/10.1002/adfm.202511675

Vancouver

Bortolotti C, Ottomaniello A, Parlanti P, Mattoli V, Natali D, Aliverti A, et al. Sensing of Chloride Ions in Sweat by Means of Printed Extended‐Gate Organic Electrochemical Transistors. Advanced Functional Materials. 2026;36(5). doi:10.1002/adfm.202511675

BibTeX
@article{Bortolotti2026,
  author = {Bortolotti, Cristiano and Ottomaniello, Andrea and Parlanti, Paola and Mattoli, Virgilio and Natali, Dario and Aliverti, Andrea and Kyndiah, Adrica and Caironi, Mario},
  title = {Sensing of Chloride Ions in Sweat by Means of Printed Extended‐Gate Organic Electrochemical Transistors},
  journal = {Advanced Functional Materials},
  year = {2026},
  volume = {36},
  number = {5},
  doi = {10.1002/adfm.202511675}
}
Kostenlos starten →