EUVIMEDEUVIMED entdecken
Crossref

Epitaxy Growth of Hofmann MOF on Monolayer MXene for ppb‐Level Room‐Temperature NO x Sensing

Dongli Li, Yinan Dong, Hua Zhang, Dagang Liu, Zhituo Geng, Chenxi Li, Hao Li, Jiayao Zhou, Zhipeng Li, Hai Lin, Weitian Zhang, Shengze Yu und 5 weitere

Advanced Functional Materials · 2026-01 · 36 (6)

DOI: 10.1002/adfm.202511574 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 13.08.2025. Verfasst von Dongli Li und 16 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nitrogen oxides (NO x ) monitoring requires sensor platforms that deliver ppb‐level sensitivity, ambient‐temperature operation, and molecular discrimination. However, rapid and selective NO x detection at room temperature remains elusive. Although 2D transition metal carbides/nitrides (MXenes) show promise in chemiresistive sensing, their susceptibility to ambient degradation and poor selectivity limit practical deployment. Here, a room‐temperature NO x sensor is developed by epitaxially growing Hofmann‐type metal–organic frameworks (Ni‐pyz) on oxygen‐terminated monolayer large‐size MXene (Ti 3 C 2 T x ). The Ni‐pyz/Ti 3 C 2 T x heterostructure exhibits enhanced sensitivity (4.8 and 5.5 times compared to Ti 3 C 2 T x ) and low detection limits (8.8 and 6.9 ppb) for NO and NO 2 , along with high selectivity and good stability (>85% response after 8 weeks). The enhanced sensitivity results from electronic coupling between the Ti 3 C 2 T x and Ni(CN) 4 , promoting charge transfer with NO x . The improved selectivity arises from the pore confinement effect of Ni‐pyz and the specific adsorption of NO x through Lewis acid‐base interactions with open Ni sites. Importantly, the dynamic response of Ni‐pyz/Ti 3 C 2 T x closely mirrors that of a trace‐level chemiluminescence NO x analyzer at low NO x concentrations, enabling high‐temporal‐resolution, long‐term atmospheric monitoring. This functional strategy overcomes the insufficiency of MXene‐based gas sensors, paving the way for the development of high‐performance sensors.

Zitieren

APA

Li, D., Dong, Y., Zhang, H., Liu, D., Geng, Z., Li, C., Li, H., Zhou, J., Li, Z., Lin, H., Zhang, W., Yu, S., Yu, S., Li, C., Huang, Y., Jiang, J., & Li, Z. (2026). Epitaxy Growth of Hofmann MOF on Monolayer MXene for ppb‐Level Room‐Temperature NO x Sensing. Advanced Functional Materials, 36(6). https://doi.org/10.1002/adfm.202511574

Vancouver

Li D, Dong Y, Zhang H, Liu D, Geng Z, Li C, et al. Epitaxy Growth of Hofmann MOF on Monolayer MXene for ppb‐Level Room‐Temperature NO x Sensing. Advanced Functional Materials. 2026;36(6). doi:10.1002/adfm.202511574

BibTeX
@article{Li2026,
  author = {Li, Dongli and Dong, Yinan and Zhang, Hua and Liu, Dagang and Geng, Zhituo and Li, Chenxi and Li, Hao and Zhou, Jiayao and Li, Zhipeng and Lin, Hai and Zhang, Weitian and Yu, Shengze and Yu, Shuyan and Li, Congju and Huang, Yongping and Jiang, Jingkun and Li, Zehui},
  title = {Epitaxy Growth of Hofmann MOF on Monolayer MXene for ppb‐Level Room‐Temperature NO x Sensing},
  journal = {Advanced Functional Materials},
  year = {2026},
  volume = {36},
  number = {6},
  doi = {10.1002/adfm.202511574}
}
Kostenlos starten →