EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ranking Magnetic Colloid Performance for Magnetic Particle Imaging and Magnetic Particle Hyperthermia

Hayden Carlton, Marzieh Salimi, Nageshwar Arepally, Gabriela Bentolila, Anirudh Sharma, Adnan Bibic, Matt Newgren, Patrick Goodwill, Anilchandra Attaluri, Preethi Korangath, Jeff W M Bulte, Robert Ivkov iD

Advanced Functional Materials · 2025-01 · 35 (2)

DOI: 10.1002/adfm.202412321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 18.10.2024. Verfasst von Hayden Carlton und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Molecular Radiation Sciences the Johns Hopkins University School of Medicine Baltimore MD 21231 USA. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NCI NIH HHS, NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic particle imaging (MPI) is an emerging modality that can address longstanding technological challenges encountered with magnetic particle hyperthermia (MPH) cancer therapy. MPI is a tracer technology compatible with MPH for which magnetic nanoparticles (MNPs) provide signal for MPI and heat for MPH. Identifying whether a specific MNP formulation is suitable for both modalities is essential for clinical implementation. Current models predict that functional requirements of each modality impose conflicting demands on nanoparticle magnetic properties. This objective here is to develop a measurement and ranking scheme based on end‐use performance to streamline evaluation of candidate MNP formulations. The measured MPI point‐spread function (PSF) and specific loss power (SLP) is combined to generate a single numerical value for comparison on a relative ranking scale, or figure of merit (FoM). 12 aqueous iron‐containing formulations are evaluated, including FDA‐approved (parenteral) iron‐containing colloids. MNPs with high (Synomag‐D70: 123.4), medium (Synomag‐D50: 63.2), and low (NanoXact: 0.147) FoM values are selected for in vivo validation of the selection scheme in subcutaneous 4T1 tumors. Results demonstrate that the proposed ranking accurately assessed the relative performance of MNPs for MPI and MPH. Data demonstrated that image quality and tumor temperature rise increased with FoM ranking, validating predictions. It isshown that the MPI signal correlated with MNP concentration in tissue. Computational heat transfer models anchored on tumor MPI data harmonized with experimental results to within an average of 2 °C when MNP content estimated from MPI data is included. Computational studies emphasized the importance of post‐injection MNP quantitation and MPI spatial resolution.

Schlagwörter

Stichwörter der Autor:innen

hysteresis heatingmagnetic hyperthermiamagnetic nanoparticlesmagnetic particle imagingnanoparticle characterizationrelaxometry

Autor:innen und Institutionen

  • Department of Radiation Oncology and Molecular Radiation Sciences the Johns Hopkins University School of Medicine Baltimore MD 21231 USA.
  • Russell H. Morgan Department of Radiology and Radiological Science Division of MR Research the Johns Hopkins University School of Medicine Baltimore MD 21205 USA.
  • Cellular Imaging Section and Vascular Biology Program Institute for Cell Engineering the Johns Hopkins University School of Medicine Baltimore MD 21205 USA.
  • Department of Mechanical Engineering School of Science Engineering and Technology The Pennsylvania State University - Harrisburg Harrisburg PA 17057 USA.
  • F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Inc. Baltimore MD 21205 USA.
  • Magnetic Insight Inc. Alameda CA 94502 USA.

ORCID-Profile: Robert Ivkov

Förderung

  • NCI NIH HHS
  • NIH HHS
  • NIBIB NIH HHS
  • National Cancer Institute

Zitieren

APA

Carlton, H., Salimi, M., Arepally, N., Bentolila, G., Sharma, A., Bibic, A., Newgren, M., Goodwill, P., Attaluri, A., Korangath, P., Bulte, J. W. M., & Ivkov, R. (2025). Ranking Magnetic Colloid Performance for Magnetic Particle Imaging and Magnetic Particle Hyperthermia. Advanced Functional Materials, 35(2). https://doi.org/10.1002/adfm.202412321

Vancouver

Carlton H, Salimi M, Arepally N, Bentolila G, Sharma A, Bibic A, et al. Ranking Magnetic Colloid Performance for Magnetic Particle Imaging and Magnetic Particle Hyperthermia. Advanced Functional Materials. 2025;35(2). doi:10.1002/adfm.202412321

BibTeX
@article{Carlton2025,
  author = {Carlton, Hayden and Salimi, Marzieh and Arepally, Nageshwar and Bentolila, Gabriela and Sharma, Anirudh and Bibic, Adnan and Newgren, Matt and Goodwill, Patrick and Attaluri, Anilchandra and Korangath, Preethi and Bulte, Jeff W M and Ivkov, Robert},
  title = {Ranking Magnetic Colloid Performance for Magnetic Particle Imaging and Magnetic Particle Hyperthermia},
  journal = {Advanced Functional Materials},
  year = {2025},
  volume = {35},
  number = {2},
  doi = {10.1002/adfm.202412321}
}
Kostenlos starten →