Integrated Piezoelectric Vascular Graft for Continuous Real‐Time Hemodynamics Monitoring

Zhiqiang Ma, Weibin Jia, Jing Zhang, Xingdao He, Shiyuan Liu, Mohamed Elhousseini Hilal, Xiang Zhou, Zhengbao Yang, Zonggang Chen, Peng Shi, Bee Luan Khoo

Advanced Functional Materials · 2024-11 · 34 (48)

DOI: 10.1002/adfm.202409874 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 06.10.2024. Verfasst von Zhiqiang Ma und 10 weiteren Autor:innen. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Research Grants Council, University Grants Committee, Innovation and Technology Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vascular grafts, widely utilized in managing cardiovascular diseases (CVD), are susceptible to postoperative complications. Recent strides in intelligent vascular grafts leveraging flexible bioelectronics enable hemodynamic and vascular health monitoring. However, their practical application faces challenges, notably biomechanical compatibility and endothelialization. Here, an all‐in‐one piezoelectric vascular graft (PVG) constructed by encapsulating a polyvinylidene fluoride (PVDF) nanofiber mat with patterned silver nanowire (AgNW) electrodes between two layers of polycaprolactone (PCL) nanofiber mats is presented. The meticulously optimized PVG, featuring PVDF and PCL nanofibers with average diameters of ≈950 and 250 nm, respectively, showcases remarkable endothelialization and mechanical performance akin to native blood vessels. The exquisite piezoelectric properties of PVDF nanofibers imbue PVG with outstanding mechanical sensing capabilities, boasting a sensitivity of 11 mV kPa −1 and stability exceeding 50 000 cycles, facilitating precise hemodynamic monitoring. Notably, artificial artery model tests demonstrate PVG's ability to diagnose vascular health status accurately based on detected hemodynamic data. Furthermore, the developed PVG exhibits nontoxicity, good hemocompatibility (hemolytic ratio < 1%), and histocompatibility. This pioneering technology, validated through ex vivo and in vivo experiments, represents a significant stride in precise vascular health management, unlocking diverse potential applications.

Förderung

  • Research Grants Council, University Grants Committee
  • Innovation and Technology Fund

Zitieren

APA

Ma, Z., Jia, W., Zhang, J., He, X., Liu, S., Hilal, M. E., Zhou, X., Yang, Z., Chen, Z., Shi, P., & Khoo, B. L. (2024). Integrated Piezoelectric Vascular Graft for Continuous Real‐Time Hemodynamics Monitoring. Advanced Functional Materials, 34(48). https://doi.org/10.1002/adfm.202409874

Vancouver

Ma Z, Jia W, Zhang J, He X, Liu S, Hilal ME, et al. Integrated Piezoelectric Vascular Graft for Continuous Real‐Time Hemodynamics Monitoring. Advanced Functional Materials. 2024;34(48). doi:10.1002/adfm.202409874

BibTeX
@article{Ma2024,
  author = {Ma, Zhiqiang and Jia, Weibin and Zhang, Jing and He, Xingdao and Liu, Shiyuan and Hilal, Mohamed Elhousseini and Zhou, Xiang and Yang, Zhengbao and Chen, Zonggang and Shi, Peng and Khoo, Bee Luan},
  title = {Integrated Piezoelectric Vascular Graft for Continuous Real‐Time Hemodynamics Monitoring},
  journal = {Advanced Functional Materials},
  year = {2024},
  volume = {34},
  number = {48},
  doi = {10.1002/adfm.202409874}
}
Kostenlos starten →