EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Point‐of‐Care Sensing Platform for Multiplexed Detection of Chronic Kidney Disease Biomarkers Using Molecularly Imprinted Polymers

Yixuan Li, Liuxiong Luo, Yingqi Kong, Sophiamma George, Yujia Li, Xiaotong Guo, Xin Li, Eric Yeatman, Andrew Davenport, Ying Li, Bing Li

Advanced Functional Materials · 2024-07 · 34 (28)

DOI: 10.1002/adfm.202316865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 12.02.2024. Verfasst von Yixuan Li und 10 weiteren Autor:innen. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Society, Medical Research Council, Engineering and Physical Sciences Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chronic kidney disease (CKD) is one of the most serious non‐communicable diseases affecting the population. In the early‐stages patients have no obvious symptoms, until it becomes life‐threatening leading end‐stage kidney failure. Therefore, it is important to early diagnose CKD to allow therapeutic interventions and progression monitoring. Here, a point‐of‐care (POC) sensing platform is reported for the simultaneous detection of three CKD biomarkers, namely creatinine, urea, and human serum albumin (HSA), using reduced graphene oxide/polydopamine‐molecularly imprinted polymer (rGO/PDA‐MIP) fabricated with novel surface‐molecularly imprinting technology. A multi‐channel electrochemical POC readout system with differential pulse voltammetry (DPV) function is developed, allowing the simultaneous detection of the three biomarkers, in combination with the surface‐MIP electrodes. This sensing platform achieves the record low limit‐of‐detection (LoD) at a femtomolar level for all three analytes, with wide detection ranges covering their physiological concentrations. Clinical validation is performed by measuring these analytes in serum and urine from healthy controls and patients with CKD. The average recovery rate is 81.8–119.1% compared to the results obtained from the hospital, while this platform is more cost‐effective, user‐friendly, and requires less sample‐to‐result time, showing the potential to be deployed in resource‐limited settings for the early diagnosis and tracking progression of CKD.

Förderung

  • Royal Society
  • Medical Research Council
  • Engineering and Physical Sciences Research Council
  • Alzheimer’s Research UK
  • China Scholarship Council

Zitieren

APA

Li, Y., Luo, L., Kong, Y., George, S., Li, Y., Guo, X., Li, X., Yeatman, E., Davenport, A., Li, Y., & Li, B. (2024). A Point‐of‐Care Sensing Platform for Multiplexed Detection of Chronic Kidney Disease Biomarkers Using Molecularly Imprinted Polymers. Advanced Functional Materials, 34(28). https://doi.org/10.1002/adfm.202316865

Vancouver

Li Y, Luo L, Kong Y, George S, Li Y, Guo X, et al. A Point‐of‐Care Sensing Platform for Multiplexed Detection of Chronic Kidney Disease Biomarkers Using Molecularly Imprinted Polymers. Advanced Functional Materials. 2024;34(28). doi:10.1002/adfm.202316865

BibTeX
@article{Li2024,
  author = {Li, Yixuan and Luo, Liuxiong and Kong, Yingqi and George, Sophiamma and Li, Yujia and Guo, Xiaotong and Li, Xin and Yeatman, Eric and Davenport, Andrew and Li, Ying and Li, Bing},
  title = {A Point‐of‐Care Sensing Platform for Multiplexed Detection of Chronic Kidney Disease Biomarkers Using Molecularly Imprinted Polymers},
  journal = {Advanced Functional Materials},
  year = {2024},
  volume = {34},
  number = {28},
  doi = {10.1002/adfm.202316865}
}