EUVIMEDEUVIMED entdecken
Crossref

Fabrication of Flexible and Conductive Microneedle Array Electrodes from Silk Fibroin by Mesoscopic Engineering

Xiao Wang, Wu Qiu, Changsheng Lu, Zerong Jiang, Chen Hou, Yanru Li, Yan Wang, Haiman Du, Jin Zhou, Xiang Yang Liu

Advanced Functional Materials · 2024-07 · 34 (30)

DOI: 10.1002/adfm.202311535 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 11.04.2024. Verfasst von Xiao Wang und 9 weiteren Autor:innen. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional electrodes are of significant challenges in acquiring bioelectric signals concerning a high signal‐to‐noise ratio (SNR), long‐term and comfortable wear, low motional noise, etc. To resolve these issues, silk fibroin (SF) materials are adopted to create flexible microneedle array electrodes (FMNA‐electrode) based on meso‐engineering. The research approaches involve constructing flexible conductive electrodes from non‐conductive and bristle‐regenerated SF. By controlling the molecular interchain nucleation in the refolding process of unfolded regenerated SF molecules, this goal can be achieved. In this process, silver nanowires (Ag NWs) are adopted as meso‐dopants to reconstruct the meso‐electronic structure of SF films at the surface, while polyurethane (PU) is selected as molecular templates to facilitate the molecular nucleation in the refolding of SF molecules. This leads to the occurrence of SF‐PU meso‐hybridization, giving rise to more flexible meso‐hybridized SF. The SF‐PU FMNA‐electrode demonstrates biocompatibility, comfort wearing, long‐term monitoring capability, low motional noise, and a high SNR in the application of collecting ECG, EMG, and EOG signals. The outperformance of SF‐PU FMNA‐electrode is superior to both conventional wet and commercially available dry electrodes, paving the way for the next generation of flexible, skin‐friendly, durable, and high‐performance health monitoring devices and brain‐machine interfaces.

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Planning Project of Guangdong Province

Zitieren

APA

Wang, X., Qiu, W., Lu, C., Jiang, Z., Hou, C., Li, Y., Wang, Y., Du, H., Zhou, J., & Liu, X. Y. (2024). Fabrication of Flexible and Conductive Microneedle Array Electrodes from Silk Fibroin by Mesoscopic Engineering. Advanced Functional Materials, 34(30). https://doi.org/10.1002/adfm.202311535

Vancouver

Wang X, Qiu W, Lu C, Jiang Z, Hou C, Li Y, et al. Fabrication of Flexible and Conductive Microneedle Array Electrodes from Silk Fibroin by Mesoscopic Engineering. Advanced Functional Materials. 2024;34(30). doi:10.1002/adfm.202311535

BibTeX
@article{Wang2024,
  author = {Wang, Xiao and Qiu, Wu and Lu, Changsheng and Jiang, Zerong and Hou, Chen and Li, Yanru and Wang, Yan and Du, Haiman and Zhou, Jin and Liu, Xiang Yang},
  title = {Fabrication of Flexible and Conductive Microneedle Array Electrodes from Silk Fibroin by Mesoscopic Engineering},
  journal = {Advanced Functional Materials},
  year = {2024},
  volume = {34},
  number = {30},
  doi = {10.1002/adfm.202311535}
}
Kostenlos starten →