EUVIMEDEUVIMED entdecken
Crossref

N‐Heterocyclic Carbene–Graphene Nanotransistor Based on Covalent Bond for Ultrastable Biosensors

Kyung Ho Kim, Sung Eun Seo, Seon Joo Park, Jinyeong Kim, Chul Soon Park, Thanh‐Hai Le, Chang‐Seop Lee, Yu Kyung Kim, Hye‐Yeon Kim, Sangmi Jun, Jisung Kwak, Yeon Kyung Lee und 3 weitere

Advanced Functional Materials · 2024-05 · 34 (21)

DOI: 10.1002/adfm.202310377 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 31.01.2024. Verfasst von Kyung Ho Kim und 14 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korea Institute of Science and Technology, National Research Council of Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fatal pathogenic organisms have been detected by various point‐of‐care tests (PoCTs) in clinical samples. PoCTs based on portable electrical devices are able to detect organisms in simple and rapid method. Although electrical PoCT devices show ultra sensitivity when detecting pathogens in standard samples, their industrialization has been limited due to low reproducibility, sensitivity, and specificity, resulting from nonspecific binding issues by media. In this research, a perpendicular N‐heterocyclic carbene self‐assembled monolayer (NHC‐SAM) conjugated on graphene micropattern field‐effect transistors (NGMFETs) is first demonstrated for monitoring pathogens. Two single bonds of NHCSAM on GM are investigated via density functional theory (DFT) and surface analyses. Bioreceptors are conjugated on the side gate‐modulated NGMFET for ultra‐stable on‐site detection. The side‐gated BNGMFETs system displayed remarkable performance in the detection of the following: i) SARS‐CoV‐2 spike protein S1 (limit of detection (LOD): ≈10 pg mL −1 ) in CTM, ii) O. tsutsugamushi Ab (LOD: ≈1 pg mL −1 ), and iii) E. coli (LOD: 10° CFU mL −1 ) in serum. Compared to commercial methodology, the platform presents 10 2 times higher LODs towards those pathogens in clinical samples with higher reproducibility. Based on these results, side‐gated BNGMFETs can be utilized as universal PoCT during pandemics.

Förderung

  • National Research Foundation of Korea
  • Korea Institute of Science and Technology
  • National Research Council of Science and Technology

Zitieren

APA

Kim, K. H., Seo, S. E., Park, S. J., Kim, J., Park, C. S., Le, T., Lee, C., Kim, Y. K., Kim, H., Jun, S., Kwak, J., Lee, Y. K., Yoon, H., Song, H. S., & Kwon, O. S. (2024). N‐Heterocyclic Carbene–Graphene Nanotransistor Based on Covalent Bond for Ultrastable Biosensors. Advanced Functional Materials, 34(21). https://doi.org/10.1002/adfm.202310377

Vancouver

Kim KH, Seo SE, Park SJ, Kim J, Park CS, Le T, et al. N‐Heterocyclic Carbene–Graphene Nanotransistor Based on Covalent Bond for Ultrastable Biosensors. Advanced Functional Materials. 2024;34(21). doi:10.1002/adfm.202310377

BibTeX
@article{Kim2024,
  author = {Kim, Kyung Ho and Seo, Sung Eun and Park, Seon Joo and Kim, Jinyeong and Park, Chul Soon and Le, Thanh‐Hai and Lee, Chang‐Seop and Kim, Yu Kyung and Kim, Hye‐Yeon and Jun, Sangmi and Kwak, Jisung and Lee, Yeon Kyung and Yoon, Hyeonseok and Song, Hyun Seok and Kwon, Oh Seok},
  title = {N‐Heterocyclic Carbene–Graphene Nanotransistor Based on Covalent Bond for Ultrastable Biosensors},
  journal = {Advanced Functional Materials},
  year = {2024},
  volume = {34},
  number = {21},
  doi = {10.1002/adfm.202310377}
}
Kostenlos starten →