EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Screen‐Printed Flexible Piezoelectric Force Sensor Array with Electromagnetic Interference Shielding

Joseph Faudou, Mohammed Benwadih, Arnaud Gabas, Lina Kadura, Minh‐Quyen Le, Daniel Grinberg, Pierre‐Jean Cottinet

Advanced Engineering Materials · 18.02.2026 · 28 (4)

DOI: 10.1002/adem.202502361 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Engineering Materials, online erschienen am 17.01.2026. Verfasst von Joseph Faudou und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Agence Nationale de la Recherche.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible force sensor arrays have gained significant interest in recent years for healthcare applications, particularly with the rising prevalence of wearable devices. However, several challenges must be overcome before their widespread adoption. This study presents a flexible piezoelectric array tailored for low frequency applications, such as tactile sensing and cardiovascular monitoring. The proposed array is fabricated using a fast and cost‐effective screen‐printing process integrating flexible electromagnetic interference (EMI) shielding. Its structure is intentionally designed to accurately measure forces across complex surfaces, with miniaturized interface electronics capable of processing up to 128 piezoelectric signals simultaneously. By dividing the device into two distinct sections, the design of the EMI shielding strikes a balance between flexibility and effectiveness. The impact on the electromechanical performance is minimal, with a slight decrease in sensitivity of only 25%, while the benefits to signal quality are significant. Notably, measurement noise is eliminated up to 10 kHz, well above the relevant frequency ranges for the targeted applications. Other electromechanical couplings such as triboelectricity and flexoelectricity are also effectively mitigated. The limitations of this study are discussed, and a novel sensor structure is proposed as a perspective, offering exceptional performance with a sensitivity in compression of 700 pC N −1 .

Förderung

  • Agence Nationale de la Recherche

Zitieren

APA

Faudou, J., Benwadih, M., Gabas, A., Kadura, L., Le, M., Grinberg, D., & Cottinet, P. (2026). Screen‐Printed Flexible Piezoelectric Force Sensor Array with Electromagnetic Interference Shielding. Advanced Engineering Materials, 28(4). https://doi.org/10.1002/adem.202502361

Vancouver

Faudou J, Benwadih M, Gabas A, Kadura L, Le M, Grinberg D, et al. Screen‐Printed Flexible Piezoelectric Force Sensor Array with Electromagnetic Interference Shielding. Advanced Engineering Materials. 2026;28(4). doi:10.1002/adem.202502361

BibTeX
@article{Faudou2026,
  author = {Faudou, Joseph and Benwadih, Mohammed and Gabas, Arnaud and Kadura, Lina and Le, Minh‐Quyen and Grinberg, Daniel and Cottinet, Pierre‐Jean},
  title = {Screen‐Printed Flexible Piezoelectric Force Sensor Array with Electromagnetic Interference Shielding},
  journal = {Advanced Engineering Materials},
  year = {2026},
  volume = {28},
  number = {4},
  doi = {10.1002/adem.202502361}
}
Kostenlos starten →