Utility of automated CT perfusion software in acute ischemic stroke with large and medium vessel occlusion
Annals of Clinical and Translational Neurology · 2024
DOI: 10.1002/acn3.52207 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Clinical and Translational Neurology, 2024. Verfasst von Rezan Ashayeri Ahmadabad und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neurology, University of Alberta, Edmonton, Canada. Hauptthemen laut MEDLINE: Ischemic Stroke, Software, Computed Tomography Angiography. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Background
Early diagnosis of large vessel occlusion (LVO) in acute stroke often requires CT angiography (CTA). Automated CT perfusion (CTP) software, which identifies blood flow abnormalities, enhances LVO diagnosis and patient selection for endovascular thrombectomy (EVT). This study evaluates the sensitivity of automated CTP images in detecting perfusion abnormalities in patients with acute ischemic stroke (AIS) and LVO or medium vessel occlusion (MeVO), compared to CTA.
Methods
We screened acute ischemic stroke patients presenting within 24 h who underwent CT, CTA, and CTP as per institutional protocol. RAPID AI software processed CTP images, while neuroradiologists reviewed CTA for intracranial arterial occlusions. Sensitivity, specificity, and accuracy of automated CTP maps in detecting occlusions were assessed.
Results
Of 790 screened patients, 31 were excluded due to lack of RAPID CTP data or poor‐quality scans, leaving 759 for analysis. The median age was 71 years (IQR: 61–81), with 47% female. Among them, 678 had AIS, and 81 had AIS ruled out. CTA identified arterial occlusion in 562 patients (74%), with corresponding CTP abnormalities in 537 patients (Tmax > 6 sec). In the 197 without occlusion, CTP was negative in 161. Automated CTP maps had a sensitivity of 95.55% (CI 95: 93.50–97.10%), specificity of 81.73% (CI 95: 75.61–86.86%), negative predictive value of 98.22% (CI 95: 97.39–98.79%), positive predictive value of 63.54% (CI 95: 56.46–70.09%), and overall accuracy of 85.18% (CI 95: 82.45–87.64%).
Conclusions
Automated CTP maps demonstrated high sensitivity and negative predictive value for LVOs and MeVOs, suggesting their usefulness as a rapid diagnostic tool, especially in settings without expert neuroradiologists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Neurology, University of Alberta, Edmonton, Canada.
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Canada.
- Division of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Canada.
- Stanford Stroke Center, Stanford University, Palo Alto, USA.
ORCID-Profile: Rezan Ashayeri Ahmadabad
Zitieren
APA
Ashayeri Ahmadabad, R., Tran, K. H., Zhang, Y., Kate, M. P., Mishra, S., Buck, B. H., Khan, K. A., Rempel, J., Albers, G. W., & Shuaib, A. (2024). Utility of automated CT perfusion software in acute ischemic stroke with large and medium vessel occlusion. Annals of Clinical and Translational Neurology. https://doi.org/10.1002/acn3.52207
Vancouver
Ashayeri Ahmadabad R, Tran KH, Zhang Y, Kate MP, Mishra S, Buck BH, et al. Utility of automated CT perfusion software in acute ischemic stroke with large and medium vessel occlusion. Annals of Clinical and Translational Neurology. 2024. doi:10.1002/acn3.52207
BibTeX
@article{AshayeriAhmadabad2024,
author = {Ashayeri Ahmadabad, Rezan and Tran, Kim H and Zhang, Yiran and Kate, Mahesh P and Mishra, Sachin and Buck, Brian H and Khan, Khurshid A and Rempel, Jeremy and Albers, Gregory W and Shuaib, Ashfaq},
title = {Utility of automated CT perfusion software in acute ischemic stroke with large and medium vessel occlusion},
journal = {Annals of Clinical and Translational Neurology},
year = {2024},
doi = {10.1002/acn3.52207}
}
EUVIMED