Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states
Annals of Clinical and Translational Neurology · 2024-02 · 11 (2) · 389-403
DOI: 10.1002/acn3.51959 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Clinical and Translational Neurology, online erschienen am 12.01.2024. Verfasst von Tamir Avigdor und 6 weiteren Autor:innen. Beteiligte Einrichtung: Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Epilepsy, Drug Resistant Epilepsy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CIHR, Canadian Institutes of Health Research.
Abstract (Originalsprache)
Objective
The use of electrical source imaging (ESI) in assessing the source of interictal epileptic discharges (IEDs) is gaining increasing popularity in presurgical work‐up of patients with drug‐resistant focal epilepsy. While vigilance affects the ability to locate IEDs and identify the epileptogenic zone, we know little about its impact on ESI.
Methods
We studied overnight high‐density electroencephalography recordings in focal drug‐resistant epilepsy. IEDs were marked visually in each vigilance state, and examined in the sensor and source space. ESIs were calculated and compared between all vigilance states and the clinical ground truth. Two conditions were considered within each vigilance state, an unequalized and an equalized number of IEDs.
Results
The number, amplitude, and duration of IEDs were affected by the vigilance state, with N3 sleep presenting the highest number, amplitude, and duration for both conditions ( P < 0.001), while signal‐to‐noise ratio only differed in the unequalized condition ( P < 0.001). The vigilance state did not affect channel involvement ( P > 0.05). ESI maps showed no differences in distance, quality, extent, or maxima distances compared to the clinical ground truth for both conditions ( P > 0.05). Only when an absolute reference (wakefulness) was used, the channel involvement ( P < 0.05) and ESI source extent ( P < 0.01) were impacted during rapid‐eye‐movement (REM) sleep. Clustering of amplitude‐sensitive and ‐insensitive ESI maps pointed to amplitude rather than the spatial profile as the driver ( P < 0.05).
Interpretation
IED ESI results are stable across vigilance states, including REM sleep, if controlled for amplitude and IED number. ESI is thus stable and invariant to the vigilance state.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montreal, Canada.
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
- Multimodal Functional Imaging Lab, PERFORM Centre, Department of Physics, Concordia University, Montreal, Quebec, Canada.
- Department of Neurology, Duke University Medical Center, Durham, North Carolina, USA.
- Department of Biomedical Engineering, Duke Pratt School of Engineering, Durham, North Carolina, USA.
ORCID-Profile: Tamir Avigdor
Förderung
- CIHR
- Canadian Institutes of Health Research
Zitieren
APA
Avigdor, T., Abdallah, C., Afnan, J., Cai, Z., Rammal, S., Grova, C., & Frauscher, B. (2024). Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states. Annals of Clinical and Translational Neurology, 11(2), 389-403. https://doi.org/10.1002/acn3.51959
Vancouver
Avigdor T, Abdallah C, Afnan J, Cai Z, Rammal S, Grova C, et al. Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states. Annals of Clinical and Translational Neurology. 2024;11(2):389-403. doi:10.1002/acn3.51959
BibTeX
@article{Avigdor2024,
author = {Avigdor, Tamir and Abdallah, Chifaou and Afnan, Jawata and Cai, Zhengchen and Rammal, Saba and Grova, Christophe and Frauscher, Birgit},
title = {Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states},
journal = {Annals of Clinical and Translational Neurology},
year = {2024},
volume = {11},
number = {2},
pages = {389--403},
doi = {10.1002/acn3.51959}
}