Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes
Journal of Applied Clinical Medical Physics · 2026-12 · 27 (12)
DOI: 10.1002/acm2.70899 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 19.11.2026. Verfasst von Lingling Yan und 8 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
MRI‐guided radiotherapy (MRIgRT) on a 1.5 T MR‐Linac is constrained by a 22 cm maximum field length, limiting long continuous planning target volumes (PTVs). A dual‐isocenter field‐junction technique has been previously validated in a phantom study. This work presents its first clinical application in hypofractionated prostate radiotherapy. Materials and Methods A 79‐year‐old prostate cancer patient had six contiguous target volumes (PTV, CTV4000, PTVpubis, PGTVpubis, PTVp and PGTVnd), treated over 5 fractions with prescribed doses to the respective target volumes. PTVp was divided into PTVpup and PTVpdn, with a field overlap region between them. Two composite volumes were created: inferior volume (PTV, CTV4000, PTVpubis, PGTVpubis, PTVpdn) and superior volume (PTVpup, PGTVnd), each with its own isocenter. The inferior volume followed the adapt‐to‐shape (ATS) workflow. During its delivery, the superior volume was first optimized offline on daily MR images using dose feathering approach based on the inferior dose distribution. The optimized plan was then transferred for online adapt‐to‐position (ATP) adaptation. The inferior and superior volumes were combined offline for dose summation. The ArcCHECK phantom and ArcherQA Monte Carlo method were used for dose verification. Patient‐reported outcomes, including FACT‐P questionnaires, were collected during the 3‐month follow‐up.
Results
Treatment was delivered over 5 alternate‐day fractions. ArcCHECK phantom gamma passing rates, using 3%/2 mm with a 10% threshold, were 96.7%, 97.1%, and 96.0% for the inferior, superior and composite reference plans, respectively. Daily ArcherQA showed consistently high passing rates across five fractions: 97.08%–98.43% for the inferior and 98.12%–98.74% for the superior volumes. CTV4000, PTV, PTVpubis and PGTVpub all met prescribed doses. PGTVnd and PTVp had intermittent underdose relative to initial prescriptions, but all fractions met second prescription limits. Organ at risks (OARs) constraints, especially for rectum and bladder, remained within tolerance across all fractions. Total treatment time decreased from 112 min in the first fraction to 80 min in the fifth fraction. FACT‐P score declined from 69.17 at baseline to 55.5 at end‐of‐RT, partially recovering to 57.5 at 2.5 months. No urological or gastrointestinal toxicity was reported during follow‐up.
Conclusion
The proposed two‐isocenter field junction technique is clinically feasible for MRIgRT of long continuous prostate cancer PTVs. It provides a practical solution for treating long PTVs on a 1.5 T MR‐Linac.
Zitieren
APA
Yan, L., Qin, S., Liang, M., Xu, Q., Wang, N., Sun, M., Men, K., Dai, J., & Lu, N. (2026). Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes. Journal of Applied Clinical Medical Physics, 27(12). https://doi.org/10.1002/acm2.70899
Vancouver
Yan L, Qin S, Liang M, Xu Q, Wang N, Sun M, et al. Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes. Journal of Applied Clinical Medical Physics. 2026;27(12). doi:10.1002/acm2.70899
BibTeX
@article{Yan2026,
author = {Yan, Lingling and Qin, Shirui and Liang, Meng and Xu, Qianhui and Wang, Ningyu and Sun, Meng and Men, Kuo and Dai, Jianrong and Lu, Ningning},
title = {Field junction technique in MRI‐guided ultra‐hypofractionated radiotherapy for a long continuous target volume in prostate cancer: First clinical application, dosimetric and early toxicity outcomes},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {12},
doi = {10.1002/acm2.70899}
}
EUVIMED