EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimizing photon counting detector CT reconstructions for automatic vessel tracing in prostate artery embolization

Taylor Froelich, Forrest B Linch, Scott M Thompson, Michael C Jundt, Jeremy D Collins, Andrea Ferrero, Christopher P Favazza

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70835 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Taylor Froelich und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Prostate, Prostatic Neoplasms, Image Processing, Computer-Assisted. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Prostate artery embolization (PAE) requires precise visualization of complex pelvic arterial anatomy and can be aided by advanced vessel navigation tools. Photon counting detector (PCD) CT provides simultaneous ultra‐high resolution and material‐specific imaging, potentially improving automatic vessel tracing workflow for procedural planning and guidance.

Purpose

To identify, within a PCD‐CT workflow, the reconstruction that provides the most robust and consistent automatic vessel tracing for pre‐procedural PAE planning.

Methods

Ten patients underwent PCD‐CT angiography of the prostate arteries in ultra‐high‐resolution mode. Four reconstruction approaches were evaluated: conventional reconstructions with (1) standard of care kernel and (2) sharper kernel (Bv64), along with (3) monoenergetic 50 keV, and (4) iodine map spectral results. Using commercial embolization guidance software, three vessels were manually traced for each patient to establish ground truth segmentation. Subsequently, automatic vessel traces were generated using identical start/end points as the ground truth. Root mean squared error (RMSE) between automatic traces and ground truth was used to quantify tracing accuracy.

Results

Comparing individual traces, iodine maps demonstrated consistency with median RMSE of 0.7 mm (0.4 mm interquartile range (IQR)) versus 0.7 mm (12.5 mm IQR), 1.5 mm (14.7 mm IQR), and 0.8 mm (6.7 mm IQR) for Bv56, Bv64, and 50 keV reconstructions, respectively. Iodine maps produced fewer outliers, with 13.3% of traces and 40.0% of patients having one or more traces exceeding 5 mm RMSE, compared with 26.7%–36.7% of traces and 60.0%–80.0% of patients for the other reconstructions.

Conclusions

Material‐specific iodine reconstructions from PCD‐CT yield more robust automatic vessel tracing for PAE planning, offering a workflow‐compatible solution requiring minimal protocol modifications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Embolization, TherapeuticProstateProstatic NeoplasmsImage Processing, Computer-AssistedPhotonsArteriesComputed Tomography AngiographyTomography, X-Ray ComputedHumansMaleAlgorithmsRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

photon‐counting‐detector CT (PCD‐CT)procedural guidanceprostate artery embolization (PAE)workflow improvement

Autor:innen und Institutionen

  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Förderung

  • Siemens Healthineers

Zitieren

APA

Froelich, T., Linch, F. B., Thompson, S. M., Jundt, M. C., Collins, J. D., Ferrero, A., & Favazza, C. P. (2026). Optimizing photon counting detector CT reconstructions for automatic vessel tracing in prostate artery embolization. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70835

Vancouver

Froelich T, Linch FB, Thompson SM, Jundt MC, Collins JD, Ferrero A, et al. Optimizing photon counting detector CT reconstructions for automatic vessel tracing in prostate artery embolization. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70835

BibTeX
@article{Froelich2026,
  author = {Froelich, Taylor and Linch, Forrest B and Thompson, Scott M and Jundt, Michael C and Collins, Jeremy D and Ferrero, Andrea and Favazza, Christopher P},
  title = {Optimizing photon counting detector CT reconstructions for automatic vessel tracing in prostate artery embolization},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70835}
}
Kostenlos starten →