Advancing proton therapy: Dosimetric superiority of proton arc therapy over IMPT in esophageal cancer treatment
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70607 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Xiaoda Cong und 11 weiteren Autor:innen. Beteiligte Einrichtung: Corewell Health William Beaumont University Hospital, Royal oak, Michigan, USA. Hauptthemen laut MEDLINE: Esophageal Neoplasms, Radiotherapy Planning, Computer-Assisted, Proton Therapy, Organs at Risk. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Elekta, Dr. Peter Y Chen & Family fund at the Corewell Health Foundation Southeast Michigan, Ion Beam Application S.A..
Abstract (Originalsprache)
Background and aims Esophageal cancer presents significant treatment challenges due to its proximity to critical structures such as the heart, lungs, and spinal cord. While intensity‐modulated proton therapy (IMPT) improves dose conformity, it is limited by factors such as the number of beam angles and lateral penumbra. Proton arc therapy (PAT) may overcome these issues by utilizing continuous gantry rotation to enhance conformity and spare organs‐at‐risk (OARs). This study compared PAT and IMPT in esophageal cancer, focusing on dosimetric outcomes, and dose‐averaged linear energy transfer (LET d ) distributions.
Methods
A retrospective analysis was conducted on ten esophageal cancer patients with variable tumor characteristics. Treatment plans were created using Monaco v6.1 treatment planning system for both PAT and IMPT, maintaining identical robustness parameters (± 5 mm setup and ± 3.5% range uncertainties). Both modalities were prescribed a total dose of 50.4 Gy(RBE) in 28 fractions, ensuring ≥95% clinical target volume (CTV) coverage in the worst‐case scenarios. Key metrics, including conformity index (CI), heterogeneity index (HI), and LET d , were compared. Robustness evaluations were performed across 21 worst‐case scenarios to assess plan quality and OAR sparing.
Results
PAT demonstrated superior dose conformity (CI: 0.67 ± 0.17 vs. 0.54 ± 0.13; p < 0.01) and reduced lung V20 (6.88% vs. 13.44%; p < 0.01) compared to IMPT. Critical structure sparing, including reduced spinal cord doses (max dose of (30.93 ± 10.85) Gy(RBE) vs (23.22 ± 9.55) Gy(RBE), p = 0.02), was achieved without compromising CTV coverage. PAT showed higher LET d within the CTV and lower LET d in adjacent organs‐at‐risk relative to IMPT, without statistically significant differences. While the clinical significance remains uncertain, this pattern may support more refined biological dose shaping.
Conclusions
PAT emerged as a promising modality for esophageal cancer treatment, delivering improved dose conformity and reduced OAR exposure. These advantages suggest PAT's potential to decrease radiation‐associated complications and improve therapeutic outcomes, warranting further clinical validation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Corewell Health William Beaumont University Hospital, Royal oak, Michigan, USA.
- Elekta AB, Stockholm, Sweden.
ORCID-Profile: Peilin Liu
Förderung
- Elekta
- Dr. Peter Y Chen & Family fund at the Corewell Health Foundation Southeast Michigan
- Ion Beam Application S.A.
- NIH HHS
- NCI NIH HHS
- National Institutes of Health
Zitieren
APA
Cong, X., Sebastian, E., Liu, P., Li, X., Dolan, J., Dalfson, R., Soukup, M., Lessard, E., Deraniyagala, R. L., Stevens, C. W., Chen, P. Y., & Ding, X. (2026). Advancing proton therapy: Dosimetric superiority of proton arc therapy over IMPT in esophageal cancer treatment. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70607
Vancouver
Cong X, Sebastian E, Liu P, Li X, Dolan J, Dalfson R, et al. Advancing proton therapy: Dosimetric superiority of proton arc therapy over IMPT in esophageal cancer treatment. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70607
BibTeX
@article{Cong2026,
author = {Cong, Xiaoda and Sebastian, Ebin and Liu, Peilin and Li, Xiaoqiang and Dolan, James and Dalfson, Raymond and Soukup, Martin and Lessard, Etienne and Deraniyagala, Rohan L and Stevens, Craig W and Chen, Peter Y and Ding, Xuanfeng},
title = {Advancing proton therapy: Dosimetric superiority of proton arc therapy over IMPT in esophageal cancer treatment},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70607}
}
EUVIMED