EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mitral regurgitation detection and central/eccentric classification using transformer‐based deep learning in multi‐view echocardiography

Xiaofang Zhong, Jiancheng Zhang, Yuanyuan Sheng, Ying Guo, Yumei Yang, Yuxiang Huang, Hongjuan Zhao, Wei Zeng, Lixin Chen, Dong Ni, Jinfeng Xu, Wufeng Xue und 1 weitere

Journal of Applied Clinical Medical Physics · 2026-04 · 27 (4)

DOI: 10.1002/acm2.70584 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 20.04.2026. Verfasst von Xiaofang Zhong und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Shenzhen People's Hospital, (The First Affiliated Hospital, Southern University of Science and Technology; The Second Clini…. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Deep Learning, Algorithms, Echocardiography. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, a Project of Innovation of the Science and Technology Commission of Shenzhen City, a Project of International cooperative research of the Science and Technology Commission of Shenzhen City.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fully automated diagnostic echocardiography allows for broader screening, earlier diagnosis for patients with mitral regurgitation (MR). This feasibility study developed a deep learning (DL) framework to automatically detect MR in echocardiography videos and classify regurgitation samples into central or eccentric regurgitation.

Methods

We designed a Transformer‐based deep learning model for fully automatic Doppler video detection of MR. This framework can automatically detect MR and classify central or eccentric regurgitation. The algorithm was trained, validated, and tested using retrospectively selected studies. A prospective dataset of 217 patients was used as an independent test database.

Results

(a) The model demonstrated exceptional diagnostic accuracy for MR, achieving accuracy rates of 0.94(95%CI: 0.90‐0.97) and 0.92(95%CI: 0.89‐0.96) in retrospective and prospective test sets, respectively, with area under the curve (AUC) values of 0.98 (95%CI: 0.96‐1.0) and 0.97 (95%CI: 0.95‐0.99). Its performance aligned with that of middle seniority physicians. (b) The model achieved an accuracy of 0.93 in identifying central and eccentric MR across both retrospective and prospective test sets, AUC values of 0.96 (95%CI: 0.89‐0.99) and 0.95 (95%CI: 0.89‐0.98), respectively. (c) On the tasks of MR, the diagnostic performance of the model in multiple views was better than that of the parasternal long‐axis view (PLAX) alone or the apical four‐chamber view (A4C) in both retrospective and prospective datasets.

Conclusion

The Transformer‐based algorithm proposed in this study can automate and improve the efficiency of clinical workflows, screen multi‐view for the presence of MR, and assist in classifying regurgitation characteristics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyDeep LearningAlgorithmsEchocardiographyImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumansRetrospective StudiesProspective StudiesFeasibility Studies

Stichwörter der Autor:innen

centraleccentricmitral regurgitationmulti‐viewtransformer

Autor:innen und Institutionen

  • Department of Ultrasound, Shenzhen People's Hospital, (The First Affiliated Hospital, Southern University of Science and Technology; The Second Clinical Medical College, Jinan University), Shenzhen, China.
  • The National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
  • Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China.
  • Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, China.

ORCID-Profile: Yingying Liu

Förderung

  • National Natural Science Foundation of China
  • a Project of Innovation of the Science and Technology Commission of Shenzhen City
  • a Project of International cooperative research of the Science and Technology Commission of Shenzhen City
  • Shenzhen People's Hospital Clinician Scientist Training Plan
  • Shenzhen Science and Technology Program
  • Shenzhen Science and Technology Innovation Program

Zitieren

APA

Zhong, X., Zhang, J., Sheng, Y., Guo, Y., Yang, Y., Huang, Y., Zhao, H., Zeng, W., Chen, L., Ni, D., Xu, J., Xue, W., & Liu, Y. (2026). Mitral regurgitation detection and central/eccentric classification using transformer‐based deep learning in multi‐view echocardiography. Journal of Applied Clinical Medical Physics, 27(4). https://doi.org/10.1002/acm2.70584

Vancouver

Zhong X, Zhang J, Sheng Y, Guo Y, Yang Y, Huang Y, et al. Mitral regurgitation detection and central/eccentric classification using transformer‐based deep learning in multi‐view echocardiography. Journal of Applied Clinical Medical Physics. 2026;27(4). doi:10.1002/acm2.70584

BibTeX
@article{Zhong2026,
  author = {Zhong, Xiaofang and Zhang, Jiancheng and Sheng, Yuanyuan and Guo, Ying and Yang, Yumei and Huang, Yuxiang and Zhao, Hongjuan and Zeng, Wei and Chen, Lixin and Ni, Dong and Xu, Jinfeng and Xue, Wufeng and Liu, Yingying},
  title = {Mitral regurgitation detection and central/eccentric classification using transformer‐based deep learning in multi‐view echocardiography},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {4},
  doi = {10.1002/acm2.70584}
}
Kostenlos starten →