Transferability of radiomics models between deep learning and conventional CT reconstruction algorithms: A task‐based assessment for stratifying acute pancreatitis severity
Journal of Applied Clinical Medical Physics · 2026-04 · 27 (4)
DOI: 10.1002/acm2.70551 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 25.03.2026. Verfasst von Xiaobao Hu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Jiangxi Provincial Key Laboratory for Precision Pathology and Intelligent Diagnosis, Department of Radiology, the First Affiliated Hospital, Jiangxi …. Hauptthemen laut MEDLINE: Radiomics, Pancreatitis, Tomography, X-Ray Computed, Deep Learning. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Jiangxi Province Double Thousand Talent Plan, Science and Technology Research Project of Education Department of Jiangxi Province.
Abstract (Originalsprache)
Background
Extensive evidence has demonstrated the superior image quality achieved through deep learning‐based reconstruction algorithms. However, given their growing adoption in clinical imaging, the impact of these algorithms on radiomics model development warrants thorough investigation.
Purpose
To investigate the transferability of radiomics models for acute pancreatitis (AP) severity stratification across CT images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction‐Veo (ASIR‐V), and deep learning image reconstruction (DLIR) algorithms.
Methods
This retrospective study enrolled 79 AP patients who underwent contrast‐enhanced CT. Five sets of images were reconstructed with FBP, ASIR‐V at 50% blending level (AR50), and DLIR at low (DLRL), medium (DLRM), and high (DLRH) strength levels. A total of 837 radiomic features were extracted from the pancreatic parenchyma volume to generate five corresponding datasets. Radiomics models for stratifying AP severity were built on four machine learning algorithms, trained on three DLIR datasets (source datasets) and tested on AR50 and FBP datasets (target datasets). The source and target datasets were then swapped for reverse evaluation. Model transferability across datasets was assessed by comparing performance differences between source and target datasets, with area under the receiver operating characteristic curve (AUC) as the primary metric.
Results
We identified a fundamental asymmetry in model transferability. Models trained on conventional reconstructions (AR50, FBP) demonstrated robust transfer performance to all DLIR datasets, with AUC values in target datasets generally exceeding those in source datasets. In contrast, only models trained on the DLRL dataset exhibited non‐inferior transferability when transferred to both AR50 and FBP datasets, with target AUCs being comparable to or higher than those in source datasets.
Conclusions
The transferability of radiomics models across CT reconstruction algorithms is asymmetric. Radiomics models demonstrated robust transferability from AR50 and FBP datasets to DLIR datasets for AP severity stratification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Jiangxi Provincial Key Laboratory for Precision Pathology and Intelligent Diagnosis, Department of Radiology, the First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
- Jiangxi Province Medical Imaging Research Institute, Nanchang, China.
- Clinical Research Center for Medical Imaging in Jiangxi Province, Nanchang, China.
- CT Imaging Research Center, GE HealthCare China, Beijing, China.
ORCID-Profile: Xiaobao Hu, Fuqing Zhou
Förderung
- National Natural Science Foundation of China
- Jiangxi Province Double Thousand Talent Plan
- Science and Technology Research Project of Education Department of Jiangxi Province
Zitieren
APA
Hu, X., Liang, X., Huang, Z., Zhu, Y., Guo, M., Wu, Z., & Zhou, F. (2026). Transferability of radiomics models between deep learning and conventional CT reconstruction algorithms: A task‐based assessment for stratifying acute pancreatitis severity. Journal of Applied Clinical Medical Physics, 27(4). https://doi.org/10.1002/acm2.70551
Vancouver
Hu X, Liang X, Huang Z, Zhu Y, Guo M, Wu Z, et al. Transferability of radiomics models between deep learning and conventional CT reconstruction algorithms: A task‐based assessment for stratifying acute pancreatitis severity. Journal of Applied Clinical Medical Physics. 2026;27(4). doi:10.1002/acm2.70551
BibTeX
@article{Hu2026,
author = {Hu, Xiaobao and Liang, Xiao and Huang, Zhongren and Zhu, Yanyan and Guo, Mengya and Wu, Zhihua and Zhou, Fuqing},
title = {Transferability of radiomics models between deep learning and conventional CT reconstruction algorithms: A task‐based assessment for stratifying acute pancreatitis severity},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {4},
doi = {10.1002/acm2.70551}
}
EUVIMED