From data to treatment plan: An AI‐driven path for automated breast radiotherapy planning
Journal of Applied Clinical Medical Physics · 2026-03 · 27 (3)
DOI: 10.1002/acm2.70491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 02.03.2026. Verfasst von P Gallego und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology-Medical Physics, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Breast Neoplasms, Artificial Intelligence, Deep Learning. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon Europe and Horizon 2020 research and innovation programme, Ministerio de Ciencia e Innovación de España, Agència de Gestió d'Ajuts Universitaris i de Recerca.
Abstract (Originalsprache)
Background
Breast cancer is one of the most prevalent malignancies in women, with radiotherapy (RT) playing a key role in its treatment. Advances in RT techniques, such as 3D conformal radiotherapy (3D‐CRT) and intensity‐modulated radiotherapy (IMRT), have improved dose precision and reduced side effects. However, RT modality selection and treatment planning remain manual, time‐consuming, and subject to variability.
Purpose
This study presents and validates TARS‐B (Treatment Automation and Radiotherapy Selection for Breast Cancer), an automated framework that combines a deep learning‐based decision‐making module (DMF) for selecting the optimal RT technique and a fully automated treatment planning system (ATP) for generating deliverable plans that meet clinical quality standards and are deemed acceptable for clinical use. Materials and Methods TARS‐B functions in two stages. First, the DMF analyzes individual patient data to determine whether 3D‐CRT or IMRT is more appropriate. Second, the ATP generates the corresponding treatment plan. For 3D‐CRT, a field‐in‐field (FiF) method is used to enhance dose homogeneity and minimize hotspots. For IMRT, the DMF provides neural network‐based dose predictions, which are used to generate constraints for organs‐at‐risk (OARs). Both processes are fully scripted within the treatment planning system (TPS). The framework was tested on 60 breast cancer patients: 30 originally treated with 3D‐CRT and 30 with IMRT. Two analyses were conducted. First, the ATP's performance was evaluated by comparing automated plans with their manually generated clinical counterparts for both techniques. Second, the full TARS‐B pipeline was assessed by applying the DMF to select the RT modality and automatically generating the plan, comparing results to the original clinical plans. Dosimetric parameters, including planning target volume (PTV) coverage, OAR constraints, and low‐ and intermediate‐dose bath, were analyzed. Planning times were also compared.
Results
No statistically significant differences () were found between manual and automated plans in key dosimetric metrics, including PTV coverage (V95), hotspots (V105), and OAR constraints, for both 3D‐CRT and IMRT. TARS‐B confirmed the appropriateness of 3D‐CRT in all patients originally treated with it and recommended re‐planning with 3D‐CRT for 15 of 30 IMRT cases. Of these, 14 re‐plans met all criteria; one failed due to anatomical anomalies. Re‐planning led to a reduction in low‐dose bath (up to 2800 ) and intermediate‐dose bath (up to 3000 ). The reduction in intermediate‐dose bath was statistically significant (). Planning times decreased substantially: from to min for IMRT, and from to min for 3D‐CRT ().
Conclusions
TARS‐B effectively automates both the selection of the most appropriate RT technique and the generation of high‐quality treatment plans. This framework improves workflow efficiency, reduces planning time, and preserves dosimetric quality, highlighting its potential for clinical implementation in breast cancer RT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology-Medical Physics, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
- Department of Mathematics and Computer Science, University of Barcelona, Barcelona, Spain.
- Institut de Recerca Sant Pau (IR SANT PAU), Barcelona, Spain.
- Servei de Física i Protecció Radiològica, Hospital del Mar, Barcelona, Spain.
- Department of Radiation Oncology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
- Computer Vision Center, Bellaterra, Spain.
Förderung
- European Union's Horizon Europe and Horizon 2020 research and innovation programme
- Ministerio de Ciencia e Innovación de España
- Agència de Gestió d'Ajuts Universitaris i de Recerca
Zitieren
APA
Gallego, P., Ambroa, E., Pérez-Alija, J., Julià, J. C., Jornet, N., Matas, A., Anson, C., Mera, A., Tejedor, N., Vivancos, H., Ruiz, A., Barceló, M., Dominguez, A., Riu, V., Roda, J., Carrasco, P., Balocco, S., & Díaz, O. (2026). From data to treatment plan: An AI‐driven path for automated breast radiotherapy planning. Journal of Applied Clinical Medical Physics, 27(3). https://doi.org/10.1002/acm2.70491
Vancouver
Gallego P, Ambroa E, Pérez-Alija J, Julià JC, Jornet N, Matas A, et al. From data to treatment plan: An AI‐driven path for automated breast radiotherapy planning. Journal of Applied Clinical Medical Physics. 2026;27(3). doi:10.1002/acm2.70491
BibTeX
@article{Gallego2026,
author = {Gallego, P and Ambroa, E and Pérez-Alija, J and Julià, J C and Jornet, N and Matas, A and Anson, C and Mera, A and Tejedor, N and Vivancos, H and Ruiz, A and Barceló, M and Dominguez, A and Riu, V and Roda, J and Carrasco, P and Balocco, S and Díaz, O},
title = {From data to treatment plan: An AI‐driven path for automated breast radiotherapy planning},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {3},
doi = {10.1002/acm2.70491}
}
EUVIMED