EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An automated patient‐specific segment reduction‐based beam angle optimization technique for deep learning auto‐planning for early breast cancer

Michele Zeverino iD, Gian Guyer, Wendy Jeanneret-Sozzi, Fernanda Herrera, Francois Bochud, Raphaël Moeckli iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70293 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Michele Zeverino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Deep Learning, Breast Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Deep learning (DL)‐based auto‐planning has emerged as a powerful tool for optimizing radiotherapy treatment plans, reducing variability, and improving efficiency. However, current approaches often rely on predefined beam angles and arc spans, which may not be optimal for individual patients. Automated beam angle optimization can further enhance plan quality, particularly in early‐stage breast cancer radiotherapy, where precise beam configurations are crucial for balancing target coverage and organ‐at‐risk (OAR) sparing.

Purpose

This study presents an automated segment reduction‐based beam angle optimization technique to improve DL‐based auto‐planning for radiotherapy in early‐stage breast cancer. The method optimizes arc spans for volumetric‐modulated‐arc‐therapy (VMAT) and beam configurations for intensity‐modulated‐radiation‐therapy (IMRT) to improve dose distribution while reducing OAR exposure.

Methods

Plans using three different irradiation strategies—partial arc VMAT (PA‐VMAT), complex IMRT (C‐IMRT), and simple IMRT (S‐IMRT)—were generated using two full arcs for dose mimicking of the predicted dose, followed by the segment reduction performed using a stepwise PAMU (Product of segment Area and Monitor Units) thresholding approach to determine optimal arc spans and beam angles. These strategies were compared against the standard continuous partial arc VMAT (CPA‐VMAT) technique currently used in our clinical practice. Twenty left‐sided breast cancer patients treated under deep inspiration breath‐hold (DIBH) conditions were included for evaluation. Plan quality was assessed using dosimetric criteria, conformity indices, dose mimicking index (DMI), and statistical comparisons.

Results

PA‐VMAT exhibited superior OAR sparing and the best overall dose mimicking performance, reducing the heart, left lung, and right lung mean doses by 27%, 11%, and 50%, respectively, compared to CPA‐VMAT. C‐IMRT provided the best target coverage but required higher monitor units, while S‐IMRT showed suboptimal dose homogeneity. The automated segment reduction method significantly improved plan efficiency, optimizing beam angles without requiring manual intervention.

Conclusion

This study demonstrates the feasibility of an automated segment reduction‐based optimization technique for DL auto‐planning in early‐stage breast cancer. PA‐VMAT emerged as the preferred strategy, balancing plan quality, delivery efficiency, and OAR sparing. The proposed approach enhances treatment planning flexibility and will be incorporated into future clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedDeep LearningBreast NeoplasmsRadiotherapy, Intensity-ModulatedOrgans at RiskHumansFemaleRadiotherapy DosageAlgorithms

Stichwörter der Autor:innen

beam angle optimizationbreast cancer radiotherapydeep learning auto‐planningdose mimicking

Autor:innen und Institutionen

  • Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Radiation Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

ORCID-Profile: Michele Zeverino, Raphaël Moeckli

Zitieren

APA

Zeverino, M., Guyer, G., Jeanneret-Sozzi, W., Herrera, F., Bochud, F., & Moeckli, R. (2025). An automated patient‐specific segment reduction‐based beam angle optimization technique for deep learning auto‐planning for early breast cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70293

Vancouver

Zeverino M, Guyer G, Jeanneret-Sozzi W, Herrera F, Bochud F, Moeckli R. An automated patient‐specific segment reduction‐based beam angle optimization technique for deep learning auto‐planning for early breast cancer. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70293

BibTeX
@article{Zeverino2025,
  author = {Zeverino, Michele and Guyer, Gian and Jeanneret-Sozzi, Wendy and Herrera, Fernanda and Bochud, Francois and Moeckli, Raphaël},
  title = {An automated patient‐specific segment reduction‐based beam angle optimization technique for deep learning auto‐planning for early breast cancer},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70293}
}
Kostenlos starten →