Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Quanxiang Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, TCM Hospital of Yiyuan County, Yiyuan County, Shandong, China. Hauptthemen laut MEDLINE: Arachnoid Cysts, Diffusion Magnetic Resonance Imaging, Cisterna Magna, Image Processing, Computer-Assisted. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Nature Science Foundation of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To explore the utility of diffusion‐weighted imaging (DWI)‐derived apparent diffusion coefficient (ADC) and exponential apparent diffusion coefficient (eADC) parameters in differentiating mega cisterna magna (MCM) from cisterna magna arachnoid cysts (CMAC).

Methods

Retrospective analysis of MRI data from 40 MCM patients, 46 CMAC patients (confirmed via clinical follow‐up and imaging criteria), and 36 temporal arachnoid cysts (TAC) as controls was performed. Independent sample t ‐tests were used to compare ADC and eADC values among the three groups.

Results

The eADC values of MCM, CMAC, and TAC were (3.75 ± 0.27) × 10 −2 , (4.53 ± 0.54)×10 −2 , and (4.35 ± 0.30) ×10 −2 mm 2 /s, respectively. There was no significant difference in the eADC value between CMAC and TAC ( p = 0.191). However, the eADC value of MCM was significantly different from the two groups ( p = 0.000). The ADC values of MCM, CMAC, and TAC were (3.30 ± 0.08) × 10 −3 , (3.11 ± 0.12) ×10 −3 , and (2.97 ± 0.71) × 10 −3 mm 2 /s, respectively. Significant differences in ADC were observed between MCM and both CMAC and TAC ( p = 0.000/0.003).

Conclusion

DWI‐derived ADC and eADC parameters can effectively differentiate mega cisterna magna from cisterna magna arachnoid cysts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arachnoid CystsDiffusion Magnetic Resonance ImagingCisterna MagnaImage Processing, Computer-AssistedHumansMaleRetrospective StudiesFemaleAdultMiddle AgedYoung AdultDiagnosis, DifferentialAgedAdolescentChild

Stichwörter der Autor:innen

cisterna magna arachnoid cystdifferential diagnosisdiffusion‐weighted imagingmega cisterna magnatemporal arachnoid cyst

Autor:innen und Institutionen

  • Department of Radiology, TCM Hospital of Yiyuan County, Yiyuan County, Shandong, China.
  • Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.
  • Department of Radiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Province Qianfoshan Hospital, Jinan, Shandong, China.

Förderung

  • National Nature Science Foundation of China
  • National Natural Science Foundation of China

Zitieren

APA

Li, Q., Feng, Z., Cheng, H., Cao, X., Ge, Y., Shi, H., & Wang, J. Y. (2025). Differentiating mega cisterna magna from cisterna magna arachnoid cysts: The diagnostic utility of quantitative diffusion‐weighted imaging parameters. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70166

Vancouver

Li Q, Feng Z, Cheng H, Cao X, Ge Y, Shi H, et al. Differentiating mega cisterna magna from cisterna magna arachnoid cysts: The diagnostic utility of quantitative diffusion‐weighted imaging parameters. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70166

BibTeX
@article{Li2025,
  author = {Li, Quanxiang and Feng, Zhe and Cheng, Haichao and Cao, Xin and Ge, Yaping and Shi, Hao and Wang, Jun-Ying},
  title = {Differentiating mega cisterna magna from cisterna magna arachnoid cysts: The diagnostic utility of quantitative diffusion‐weighted imaging parameters},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70166}
}
Kostenlos starten →