Landmark‐based auto‐contouring of clinical target volumes for radiotherapy of nasopharyngeal cancer
Journal of Applied Clinical Medical Physics · 2024-09 · 25 (9)
DOI: 10.1002/acm2.14474 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 29.07.2024. Verfasst von Carlos Sjogreen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA. Hauptthemen laut MEDLINE: Nasopharyngeal Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Organs at Risk. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, NCI NIH HHS, National Science Foundation.
Abstract (Originalsprache)
Background
The delineation of clinical target volumes (CTVs) for radiotherapy for nasopharyngeal cancer is complex and varies based on the location and extent of disease.
Purpose
The current study aimed to develop an auto‐contouring solution following one protocol guidelines (NRG‐HN001) that can be adjusted to meet other guidelines, such as RTOG‐0225 and the 2018 International guidelines.
Methods
The study used 2‐channel 3‐dimensional U‐Net and nnU‐Net framework to auto‐contour 27 normal structures in the head and neck (H&N) region that are used to define CTVs in the protocol. To define the CTV‐Expansion (CTV1 and CTV2) and CTV‐Overall (the outer envelope of all the CTV contours), we used adjustable morphological geometric landmarks and mimicked physician interpretation of the protocol rules by partially or fully including select anatomic structures. The results were evaluated quantitatively using the dice similarity coefficient (DSC) and mean surface distance (MSD) and qualitatively by independent reviews by two H&N radiation oncologists.
Results
The auto‐contouring tool showed high accuracy for nasopharyngeal CTVs. Comparison between auto‐contours and clinical contours for 19 patients with cancers of various stages showed a DSC of 0.94 ± 0.02 and MSD of 0.4 ± 0.4 mm for CTV‐Expansion and a DSC of 0.83 ± 0.02 and MSD of 2.4 ± 0.5 mm for CTV‐Overall. Upon independent review, two H&N physicians found the auto‐contours to be usable without edits in 85% and 75% of cases. In 15% of cases, minor edits were required by both physicians. Thus, one physician rated 100% of the auto‐contours as usable (use as is, or after minor edits), while the other physician rated 90% as usable. The second physician required major edits in 10% of cases.
Conclusions
The study demonstrates the ability of an auto‐contouring tool to reliably delineate nasopharyngeal CTVs based on protocol guidelines. The tool was found to be clinically acceptable by two H&N radiation oncology physicians in at least 90% of the cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
- Department of Radiation Oncology, Karmanos Cancer Institute, Detroit, Michigan, USA.
- Department of Radiation Oncology, University of Alabama Birmingham, Birmingham, Alabama, USA.
- Department of Radiation Oncology, Stanford University, Stanford, California, USA.
ORCID-Profile: Tucker J Netherton, Skylar S Gay, Beth M Beadle
Förderung
- NCATS NIH HHS
- NCI NIH HHS
- National Science Foundation
Zitieren
APA
Sjogreen, C., Netherton, T. J., Lee, A., Soliman, M., Gay, S. S., Nguyen, C., Mumme, R., Vazquez, I., Rhee, D. J., Cardenas, C. E., Martel, M. K., Beadle, B. M., & Court, L. E. (2024). Landmark‐based auto‐contouring of clinical target volumes for radiotherapy of nasopharyngeal cancer. Journal of Applied Clinical Medical Physics, 25(9). https://doi.org/10.1002/acm2.14474
Vancouver
Sjogreen C, Netherton TJ, Lee A, Soliman M, Gay SS, Nguyen C, et al. Landmark‐based auto‐contouring of clinical target volumes for radiotherapy of nasopharyngeal cancer. Journal of Applied Clinical Medical Physics. 2024;25(9). doi:10.1002/acm2.14474
BibTeX
@article{Sjogreen2024,
author = {Sjogreen, Carlos and Netherton, Tucker J and Lee, Anna and Soliman, Moaaz and Gay, Skylar S and Nguyen, Callistus and Mumme, Raymond and Vazquez, Ivan and Rhee, Dong Joo and Cardenas, Carlos E and Martel, Mary K and Beadle, Beth M and Court, Laurence Edward},
title = {Landmark‐based auto‐contouring of clinical target volumes for radiotherapy of nasopharyngeal cancer},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
volume = {25},
number = {9},
doi = {10.1002/acm2.14474}
}
EUVIMED