Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Jonathan Redekopp und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics & Astronomy, University of Manitoba, Manitoba, Winnipeg, Canada. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Breast Neoplasms. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deep Inspiration Breath Hold (DIBH) is a respiratory‐gating technique adopted in radiation therapy to lower cardiac irradiation. When performing DIBH treatments, it is important to have a monitoring system to ensure the patient's breath hold level is stable and reproducible at each fraction. In this retrospective study, we developed a system capable of monitoring DIBH breast treatments by utilizing cine EPID images taken during treatment. Setup error and intrafraction motion were measured for all fractions of 20 left‐sided breast patients. All patients were treated with a hybrid static‐IMRT technique, with EPID images from the static fields analyzed. Ten patients had open static fields and the other ten patients had static fields partially blocked with the multileaf collimator (MLC). Three image‐processing algorithms were evaluated on their ability to accurately measure the chest wall position (CWP) in EPID images. CWP measurements were recorded along a 61‐pixel region of interest centered along the midline of the image. The median and standard deviation of the CWP were recorded for each image. The algorithm showing the highest agreement with manual measurements was then used to calculate intrafraction motion and setup error. To measure intrafraction motion, the median CWP of the first EPID frame was compared with that of the subsequent EPID images of the treatment. The maximum difference was recorded as the intrafraction motion. The setup error was calculated as the difference in median CWP between the MV DRR and the first EPID image of the lateral tangential field. The results showed that the most accurate image‐processing algorithm can identify the chest wall within 1.2 mm on both EPID and MV DRR images, and measures intrafraction motion and setup errors within 1.4 mm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedBreast NeoplasmsHumansFemaleRetrospective StudiesBreath HoldingRadiotherapy DosageBreastRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

DIBHEPID imagingautomated chest wall trackingbreast RTintrafraction motionsetup error

Autor:innen und Institutionen

  • Department of Physics & Astronomy, University of Manitoba, Manitoba, Winnipeg, Canada.
  • Medical Physics, Cancer Care Manitoba, Manitoba, Winnipeg, Canada.
  • Department of Radiology, University of Manitoba, Manitoba, Winnipeg, Canada.
  • CancerCare Manitoba Research Institute, Manitoba, Winnipeg, Canada.

Zitieren

APA

Redekopp, J., Rivest, R., Sasaki, D., Pistorius, S., & Alpuche Aviles, J. E. (2023). Automated review of patient position in DIBH breast hybrid IMRT with EPID images. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14038

Vancouver

Redekopp J, Rivest R, Sasaki D, Pistorius S, Alpuche Aviles JE. Automated review of patient position in DIBH breast hybrid IMRT with EPID images. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.14038

BibTeX
@article{Redekopp2023,
  author = {Redekopp, Jonathan and Rivest, Ryan and Sasaki, David and Pistorius, Stephen and Alpuche Aviles, Jorge E},
  title = {Automated review of patient position in DIBH breast hybrid IMRT with EPID images},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.14038}
}
Kostenlos starten →