EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Self‐configuring nnU‐Net for automatic delineation of the organs at risk and target in high‐dose rate cervical brachytherapy, a low/middle‐income country's experience

Didier Duprez, Christoph Trauernicht, Hannah Simonds, O'Brian Williams

Journal of Applied Clinical Medical Physics · 2023-08 · 24 (8)

DOI: 10.1002/acm2.13988 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 12.04.2023. Verfasst von Didier Duprez und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, Stellenbosch University, Tygerberg Academic Hospital, Cape Town, South Africa. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The high‐dose rate (HDR) brachytherapy treatment planning workflow for cervical cancer is a labor‐intensive, time‐consuming, and expertise‐driven process. These issues are amplified in low/middle‐income countries with large deficits in experienced healthcare professionals. Automation has the ability to substantially reduce bottlenecks in the planning process but often require a high level of expertise to develop.

Purpose

To implement the out of the box self‐configuring nnU‐Net package for the auto‐segmentation of the organs at risk (OARs) and high‐risk CTV (HR CTV) for Ring‐Tandem (R‐T) HDR cervical brachytherapy treatment planning.

Methods

The computed tomography (CT) scans of 100 previously treated patients were used to train and test three different nnU‐Net configurations (2D, 3DFR, and 3DCasc). The performance of the models was evaluated by calculating the Sørensen‐dice similarity coefficient, Hausdorff distance (HD), 95 th percentile Hausdorff distance, mean surface distance (MSD), and precision score for 20 test patients. The dosimetric accuracy between the manual and predicted contours was assessed by looking at the various dose volume histogram (DVH) parameters and volume differences. Three different radiation oncologists (ROs) scored the predicted bladder, rectum, and HR CTV contours generated by the best performing model. The manual contouring, prediction, and editing times were recorded.

Results

The mean DSC, HD, HD95, MSD and precision scores for our best performing model (3DFR) were 0.92/7.5 mm/3.0 mm/ 0.8 mm/0.91 for the bladder, 0.84/13.8 mm/5.3 mm/1.4 mm/0.84 for the rectum, and 0.81/8.5 mm/6.0 mm/2.2 mm/0.80 for the HR CTV. Mean dose differences (D 2cc/90% ) and volume differences were 0.08 Gy/1.3 cm 3 for the bladder, 0.02 Gy/0.7 cm 3 for the rectum, and 0.33 Gy/1.5 cm 3 for the HR CTV. On average, 65% of the generated contours were clinically acceptable, 33% requiring minor edits, 2% required major edits, and no contours were rejected. Average manual contouring time was 14.0 min, while the average prediction and editing times were 1.6 and 2.1 min, respectively.

Conclusion

Our best performing model (3DFR) provided fast accurate auto generated OARs and HR CTV contours with a large clinical acceptance rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyUterine Cervical NeoplasmsFemaleHumansRadiotherapy DosageOrgans at RiskRadiotherapy Planning, Computer-AssistedRectum

Stichwörter der Autor:innen

cervical cancerdeep learninghigh-dose rate brachytherapysegmentation

Autor:innen und Institutionen

  • Division of Medical Physics, Stellenbosch University, Tygerberg Academic Hospital, Cape Town, South Africa.
  • Department of Oncology, University Hospitals Plymouth NHS trust, Plymouth, UK.
  • Division of Radiation Oncology, Stellenbosch University, Tygerberg Academic Hospital, Cape Town, South Africa.

Zitieren

APA

Duprez, D., Trauernicht, C., Simonds, H., & Williams, O. (2023). Self‐configuring nnU‐Net for automatic delineation of the organs at risk and target in high‐dose rate cervical brachytherapy, a low/middle‐income country's experience. Journal of Applied Clinical Medical Physics, 24(8). https://doi.org/10.1002/acm2.13988

Vancouver

Duprez D, Trauernicht C, Simonds H, Williams O. Self‐configuring nnU‐Net for automatic delineation of the organs at risk and target in high‐dose rate cervical brachytherapy, a low/middle‐income country's experience. Journal of Applied Clinical Medical Physics. 2023;24(8). doi:10.1002/acm2.13988

BibTeX
@article{Duprez2023,
  author = {Duprez, Didier and Trauernicht, Christoph and Simonds, Hannah and Williams, O'Brian},
  title = {Self‐configuring nnU‐Net for automatic delineation of the organs at risk and target in high‐dose rate cervical brachytherapy, a low/middle‐income country's experience},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  volume = {24},
  number = {8},
  doi = {10.1002/acm2.13988}
}
Kostenlos starten →