EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Acquisition time reduction in pediatric 99m Tc‐DMSA planar imaging using deep learning

Shota Ichikawa iD, Hiroyuki Sugimori iD, Koki Ichijiri, Takaaki Yoshimura, Akio Nagaki

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.13978 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Shota Ichikawa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Hokkaido University, Sapporo, Japan. Hauptthemen laut MEDLINE: Technetium Tc 99m Dimercaptosuccinic Acid, Deep Learning. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Given the potential risk of motion artifacts, acquisition time reduction is desirable in pediatric 99m Tc‐dimercaptosuccinic acid (DMSA) scintigraphy. The aim of this study was to evaluate the performance of predicted full‐acquisition‐time images from short‐acquisition‐time pediatric 99m Tc‐DMSA planar images with only 1/5th acquisition time using deep learning in terms of image quality and quantitative renal uptake measurement accuracy.

Methods

One hundred and fifty‐five cases that underwent pediatric 99m Tc‐DMSA planar imaging as dynamic data for 10 min were retrospectively collected for the development of three deep learning models (DnCNN, Win5RB, and ResUnet), and the generation of full‐time images from short‐time images. We used the normalized mean squared error (NMSE), peak signal‐to‐noise ratio (PSNR), and structural similarity index metrics (SSIM) to evaluate the accuracy of the predicted full‐time images. In addition, the renal uptake of 99m Tc‐DMSA was calculated, and the difference in renal uptake from the reference full‐time images was assessed using scatter plots with Pearson correlation and Bland–Altman plots.

Results

The predicted full‐time images from the deep learning models showed a significant improvement in image quality compared to the short‐time images with respect to the reference full‐time images. In particular, the predicted full‐time images obtained by ResUnet showed the lowest NMSE (0.4 [0.4−0.5] %) and the highest PSNR (55.4 [54.7−56.1] dB) and SSIM (0.997 [0.995−0.997]). For renal uptake, an extremely high correlation was achieved in all short‐time and three predicted full‐time images ( R 2 > 0.999 for all). The Bland–Altman plots showed the lowest bias (−0.10) of renal uptake in ResUnet, while short‐time images showed the lowest variance (95% confidence interval: −0.14, 0.45) of renal uptake.

Conclusions

Our proposed method is capable of producing images that are comparable to the original full‐acquisition‐time images, allowing for a reduction of acquisition time/injected dose in pediatric 99m Tc‐DMSA planar imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Technetium Tc 99m Dimercaptosuccinic AcidDeep LearningChildHumansRetrospective StudiesRadionuclide ImagingKidneyRadiopharmaceuticals

Stichwörter der Autor:innen

acquisition time reductiondeep learningimage quality assessmentpediatric 99mTc-DMSA scintigraphyrenal uptake

Substanzen

Technetium Tc 99m Dimercaptosuccinic AcidRadiopharmaceuticals

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Hokkaido University, Sapporo, Japan.
  • Department of Radiological Technology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan.
  • Faculty of Health Sciences, Hokkaido University, Sapporo, Japan.

ORCID-Profile: Shota Ichikawa, Hiroyuki Sugimori

Zitieren

APA

Ichikawa, S., Sugimori, H., Ichijiri, K., Yoshimura, T., & Nagaki, A. (2023). Acquisition time reduction in pediatric 99m Tc‐DMSA planar imaging using deep learning. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.13978

Vancouver

Ichikawa S, Sugimori H, Ichijiri K, Yoshimura T, Nagaki A. Acquisition time reduction in pediatric 99m Tc‐DMSA planar imaging using deep learning. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.13978

BibTeX
@article{Ichikawa2023,
  author = {Ichikawa, Shota and Sugimori, Hiroyuki and Ichijiri, Koki and Yoshimura, Takaaki and Nagaki, Akio},
  title = {Acquisition time reduction in pediatric 99m Tc‐DMSA planar imaging using deep learning},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.13978}
}
Kostenlos starten →