Rapid Detection and Monitoring of Flavobacterium psychrophilum in Water by Using a Handheld, Field-Portable Quantitative PCR System
Journal of Aquatic Animal Health · 01.12.2018 · 30 (4) · 302-311
DOI: 10.1002/aah.10046 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Aquatic Animal Health, online erschienen am 22.11.2018. Verfasst von Phong L Nguyen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Smith-Root, Inc., 16603 Northeast 50th Avenue, Vancouver, Washington, 98686, USA. Hauptthemen laut MEDLINE: Water Microbiology. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: University of Idaho’s Aquaculture Research Center, University of Idaho.
Abstract (Originalsprache)
Advances in technology are making it easier for rapid field detection of microbes in aquaculture. Specifically, real-time quantitative PCR (qPCR) analysis, which has traditionally been confined to laboratory-based protocols, is now available in a handheld, field-portable system. The feasibility of using the Biomeme handheld qPCR system for rapid (<50 min) on-site detection and monitoring of Flavobacterium psychrophilum from filtered water samples was evaluated. Paired water samples were collected over a 23-d period from microcosm tanks that housed fish injected with known levels of F. psychrophilum. Water samples were filtered through 0.45-μm nitrocellulose filters and were analyzed with both the Biomeme qPCR platform and a traditional bench qPCR protocol. The two methods identified similar fluctuations in F. psychrophilum DNA throughout the study. Standard curves relating quantification cycles to the number of F. psychrophilum colony-forming units (CFU) were constructed and analyzed; results indicated that CFU increased rapidly between days 6 and 8 of the trial and then progressively decreased during the remaining 15 d. Average calculated log10(CFU/mL) values were significantly correlated between the two platforms. Rapid, field-based qPCR can be incorporated into daily water quality monitoring protocols to help detect and monitor microbes in aquaculture systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Smith-Root, Inc., 16603 Northeast 50th Avenue, Vancouver, Washington, 98686, USA.
- Florida Department of Agriculture and Consumer Services, Bronson Animal Disease Diagnostic Laboratory, 2700 North John Young Parkway, Kissimmee, Florida, 34741, USA.
- Biomeme, 1015 Chestnut Street, Suite 1401, Philadelphia, Pennsylvania, 19107, USA.
- Syndel, 1441 Smith Road, Ferndale, Washington, 98248, USA.
- Department of Fish and Wildlife Sciences and Aquaculture Research Institute, University of Idaho, 875 Perimeter Drive, Moscow, Idaho, 83844, USA.
Förderung
- University of Idaho’s Aquaculture Research Center
- University of Idaho
Zitieren
APA
Nguyen, P. L., Sudheesh, P. S., Thomas, A. C., Sinnesael, M., Haman, K., & Cain, K. D. (2018). Rapid Detection and Monitoring of Flavobacterium psychrophilum in Water by Using a Handheld, Field-Portable Quantitative PCR System. Journal of Aquatic Animal Health, 30(4), 302-311. https://doi.org/10.1002/aah.10046
Vancouver
Nguyen PL, Sudheesh PS, Thomas AC, Sinnesael M, Haman K, Cain KD. Rapid Detection and Monitoring of Flavobacterium psychrophilum in Water by Using a Handheld, Field-Portable Quantitative PCR System. Journal of Aquatic Animal Health. 2018;30(4):302-311. doi:10.1002/aah.10046
BibTeX
@article{Nguyen2018,
author = {Nguyen, Phong L and Sudheesh, Ponnerassery S and Thomas, Austen C and Sinnesael, Mieke and Haman, Katherine and Cain, Kenneth D},
title = {Rapid Detection and Monitoring of Flavobacterium psychrophilum in Water by Using a Handheld, Field-Portable Quantitative PCR System},
journal = {Journal of Aquatic Animal Health},
year = {2018},
volume = {30},
number = {4},
pages = {302--311},
doi = {10.1002/aah.10046}
}
EUVIMED