This study analyzed the flexural buckling behavior of light‐gauge built‐up compression members joined by self‐drilling screws by using the energy method. A nonconventional mechanical model that simulates the flexural buckling behavior of a built‐up member was proposed, and the contradictions of Bleich's model were described. A simple design formula that directly reflects the parameters of built‐up members was derived based on the proposed model. Furthermore, to ensure flexural buckling as a single unit member, the required stiffening stiffness and number of self‐drilling screws were proposed.
Zitieren
APA
Mitsui, K., Sato, A., & Ikarashi, K. (2023). Required number of self‐drilling screws for built‐up column comprising cold‐formed lipped channel sections to ensure flexural buckling as a single unit member. JAPAN ARCHITECTURAL REVIEW, 6(1). https://doi.org/10.1002/2475-8876.12354
Vancouver
Mitsui K, Sato A, Ikarashi K. Required number of self‐drilling screws for built‐up column comprising cold‐formed lipped channel sections to ensure flexural buckling as a single unit member. JAPAN ARCHITECTURAL REVIEW. 2023;6(1). doi:10.1002/2475-8876.12354
BibTeX
@article{Mitsui2023,
author = {Mitsui, Kazuya and Sato, Atsushi and Ikarashi, Kikuo},
title = {Required number of self‐drilling screws for built‐up column comprising cold‐formed lipped channel sections to ensure flexural buckling as a single unit member},
journal = {JAPAN ARCHITECTURAL REVIEW},
year = {2023},
volume = {6},
number = {1},
doi = {10.1002/2475-8876.12354}
}
EUVIMED