EUVIMEDEUVIMED entdecken
Multizentrische StudieRandomisierte kontrollierte StudieOpen Access

Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery

Alexandria G Cousart, Colleen M Kiernan, Parker A Willmon, Giju Thomas, Tracy S Wang, Paul G Gauger, Quan-Yang Duh, Hunter J Underwood, Anee Jackson, Anuradha Patel, Anita Mahadevan-Jansen, Carmen C Solórzano

JAMA Surgery · 01.09.2025 · 160 (9) · 936

DOI: 10.1001/jamasurg.2025.2233 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift JAMA Surgery, erschienen am 01.09.2025. Verfasst von Alexandria G Cousart und 11 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, Tennessee. Hauptthemen laut MEDLINE: Hypoparathyroidism, Intraoperative Complications, Optical Imaging, Parathyroid Glands. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance Inadvertent removal and damage to parathyroid glands (PGs) can lead to hypoparathyroidism, making it crucial to accurately identify and preserve these glands during parathyroidectomy and thyroidectomy.

Objective

To assess if fiber-based near-infrared autofluorescence (NIRAF) increases the number of intraoperatively identified PGs and reduces the occurrence of hypoparathyroidism. Design, Setting, and Participants This multicenter randomized clinical trial with a 6-month follow-up was conducted between March 2020 and July 2024. It included 4 medical centers across the US, 4 senior (more than 10 years of experience) and 3 junior (less than 5 years of experience) surgeons. A total of 754 patients were enrolled and 752 were randomized, including 398 patients (2 withdrew) who underwent parathyroidectomy and 354 patients who had total/completion thyroidectomy. Data were analyzed from March 2020 to January 2025.

Interventions

Use of fiber-based NIRAF during thyroidectomy and parathyroidectomy. Main Outcomes and Measures The primary outcome was the mean number of PGs identified intraoperatively. The secondary outcome was the rate of hypoparathyroidism (transient and at last follow-up).

Results

Of 752 patients randomized, 712 were analyzed for the primary outcome (94.4%) (overall median [IQR] age, 59 [25] years; 516 females [68.4%]). A total of 161 underwent parathyroidectomy with NIRAF, while 159 had conventional surgery. Additionally, 176 underwent thyroidectomy using NIRAF and 178 had traditional surgery. The mean number of PGs identified during parathyroidectomy was not significantly higher when using NIRAF for focused procedures (mean, NIRAF, 1.6; 95% CI, 1.4-1.8 vs control, 1.5; 95% CI, 1.4-1.7). During bilateral explorations, the surgeons improved in the mean number of PGs identified when using NIRAF (mean NIRAF, 3.5; 95% CI, 3.4-3.7 vs control, 3.2; 95% CI, 3.0-3.4; P < .001). During thyroidectomy, the mean number of PGs identified increased when using NIRAF (mean NIRAF, 3.3; 95% CI, 3.2-3.4 vs control, 2.8; 95% CI, 2.7-3.0; P < .001). There was no significant difference in hypoparathyroidism after thyroidectomy, either transient (NIRAF: 48 of 173 patients [27.8%]; control: 44 of 169 patients [26%]) or at the last follow-up (NIRAF: 3 of 176 patients [1.7%]; control: 6 of 176 patients [3.4%]). Conclusions and Relevance Fiber-based NIRAF can increase the number of PGs identified during thyroidectomy and bilateral exploration parathyroidectomy without increasing the duration of the surgery. Trial Registration ClinicalTrials.gov Identifiers: NCT05579782 , NCT05022667 , NCT05022641 , NCT04281875 , NCT04299425 , NCT05152927

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypoparathyroidismIntraoperative ComplicationsOptical ImagingParathyroid GlandsParathyroidectomyThyroidectomyAdultAgedFemaleHumansMaleMiddle Aged

Autor:innen und Institutionen

  • Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, Tennessee.
  • Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.
  • Department of Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Department of Surgery, Medical College of Wisconsin, Milwaukee.
  • Department of Surgery, University of Michigan, Ann Arbor.
  • Department of Surgery, University of California, San Francisco.

Zitieren

APA

Cousart, A. G., Kiernan, C. M., Willmon, P. A., Thomas, G., Wang, T. S., Gauger, P. G., Duh, Q. Y., Underwood, H. J., Jackson, A., Patel, A., Mahadevan-Jansen, A., & Solórzano, C. C. (2025). Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery. JAMA Surgery, 160(9), 936. https://doi.org/10.1001/jamasurg.2025.2233

Vancouver

Cousart AG, Kiernan CM, Willmon PA, Thomas G, Wang TS, Gauger PG, et al. Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery. JAMA Surgery. 2025;160(9):936. doi:10.1001/jamasurg.2025.2233

BibTeX
@article{Cousart2025,
  author = {Cousart, Alexandria G and Kiernan, Colleen M and Willmon, Parker A and Thomas, Giju and Wang, Tracy S and Gauger, Paul G and Duh, Quan-Yang and Underwood, Hunter J and Jackson, Anee and Patel, Anuradha and Mahadevan-Jansen, Anita and Solórzano, Carmen C},
  title = {Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery},
  journal = {JAMA Surgery},
  year = {2025},
  volume = {160},
  number = {9},
  pages = {936},
  doi = {10.1001/jamasurg.2025.2233}
}
Kostenlos starten →