EUVIMEDEUVIMED entdecken
VergleichsstudieKlinische StudieOpen Access

Comparing Self-Fitting Strategies for Over-the-Counter Hearing Aids

Megan Knoetze, Vinaya Manchaiah, Karina De Sousa, David R Moore, De Wet Swanepoel

JAMA Otolaryngology–Head & Neck Surgery · 2024

DOI: 10.1001/jamaoto.2024.2007 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift JAMA Otolaryngology–Head & Neck Surgery, 2024. Verfasst von Megan Knoetze und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Speech-language Pathology and Audiology, University of Pretoria, Pretoria, South Africa. Hauptthemen laut MEDLINE: Hearing Aids, Cross-Over Studies. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCD NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance Fewer than 20% of US adults with hearing loss use hearing aids due to barriers like high cost. Over-the-counter (OTC) hearing aids offer a potential solution, incorporating self-fitting strategies via smartphone apps. Self-fitting strategies have been validated for Food and Drug Administration (FDA)–approved OTC hearing aids compared with prescription-based approaches. However, no direct comparative analysis exists between in situ audiometry and self-adjustment strategies using self-fitting OTC (OTC-SF) hearing aids.

Objective

To compare self-adjustment and in situ audiometry self-fitting strategies in OTC-SF hearing aids for adults with mild to moderate hearing difficulties.

Design

Settings and Participants A crossover, within-participant pseudorandomized clinical trial was conducted between July and November 2023. Twenty-eight participants were pseudo-randomly assigned to 1 of the 2 self-fitting strategies, and they experienced both interventions for 4 consecutive weeks.

Interventions

The self-adjustment group manually adjusted settings, including overall gain and spectral tilt, using Lexie B2 hearing aids, while the in situ audiometry group used Lexie B2 Plus hearing aids (Lexie Hearing by hearX Group), with an automated fitting based on in situ tests conducted through the app. Main Outcomes and Measures The primary outcome was Abbreviated Profile of Hearing Aid Benefit (APHAB). Secondary outcomes were International Outcome Inventory for Hearing Aids (IOI-HA), speech-in-noise tests (DIN and QuickSIN), and real-ear measurements (REMs). Measures were completed at baseline and after the 4-week field trial using each strategy.

Results

Twenty-eight participants (mean [SD] age, 60.2 [12.0] years) were included; 14 men and 14 women. Self-adjustment and in situ audiometry strategies produced no clinically meaningful differences across various outcome measures, including overall APHAB benefit (Cohen d = 0.2; 95% CI, −0.2 to 0.6) and overall IOI-HA satisfaction (Rosenthal r = 0.0; 95% CI, −0.3 to 0.2). Self-adjustment users reported higher satisfaction (Rosenthal r = −0.4; 95% CI, −0.6 to −0.1) and longer daily use (Rosenthal r = −0.3; 95% CI, –0.5 to 0.0) compared with those using in situ audiometry. No clinically meaningful differences were observed in speech-in-noise benefit and real-ear measurements. Conclusion and Relevance In this clinical trial of OTC-SF hearing aids, self-adjustment and in situ audiometry strategies resulted in similar outcomes. However, self-adjustment may produce higher satisfaction and longer daily use, highlighting the potential advantages of active user involvement in the fitting process. Further investigation is needed for long-term outcomes.

Trial registration

ClinicalTrials.gov Identifier: NCT05782153

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hearing AidsCross-Over StudiesHumansMaleFemaleMiddle AgedAgedAudiometrySelf CareMobile ApplicationsHearing LossPatient SatisfactionAdultProsthesis Fitting

Autor:innen und Institutionen

  • Department of Speech-language Pathology and Audiology, University of Pretoria, Pretoria, South Africa.
  • Virtual Hearing Lab, a Collaborative initiative between the University of Colorado School of Medicine, Aurora, Colorado, and the University of Pretoria, Pretoria, South Africa.
  • Department of Otolaryngology-Head and Neck Surgery, University of Colorado School of Medicine, Aurora, Colorado.
  • UCHealth Hearing and Balance, University of Colorado Hospital, Aurora.
  • Department of Speech and Hearing, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal, India.
  • Communication Sciences Research Center, Patient Services Research, Cincinnati Children's Hospital Medical Center and University of Cincinnati, Cincinnati, Ohio.

Förderung

  • NIDCD NIH HHS

Zitieren

APA

Knoetze, M., Manchaiah, V., De Sousa, K., Moore, D. R., & Swanepoel, W. (2024). Comparing Self-Fitting Strategies for Over-the-Counter Hearing Aids. JAMA Otolaryngology–Head & Neck Surgery. https://doi.org/10.1001/jamaoto.2024.2007

Vancouver

Knoetze M, Manchaiah V, De Sousa K, Moore DR, Swanepoel W. Comparing Self-Fitting Strategies for Over-the-Counter Hearing Aids. JAMA Otolaryngology–Head & Neck Surgery. 2024. doi:10.1001/jamaoto.2024.2007

BibTeX
@article{Knoetze2024,
  author = {Knoetze, Megan and Manchaiah, Vinaya and De Sousa, Karina and Moore, David R and Swanepoel, De Wet},
  title = {Comparing Self-Fitting Strategies for Over-the-Counter Hearing Aids},
  journal = {JAMA Otolaryngology–Head & Neck Surgery},
  year = {2024},
  doi = {10.1001/jamaoto.2024.2007}
}
Kostenlos starten →