High-Sensitivity Troponin Pathway and Emergency Department Length of Stay

Leon Z Jia, Narek Israelyan, Frances S Shofer, Sameh Saleh, Jeffrey Moon, Mika Epps, Joy Iocca, Sean Foster, Srinath Adusumalli, Charlene Bierl, Keith Hemmert

JAMA Network Open · 10.11.2026 · 9 (11) · e2642980

DOI: 10.1001/jamanetworkopen.2026.42980 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JAMA Network Open, online erschienen am 10.11.2026. Verfasst von Leon Z Jia und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Beth Israel Lahey Health System, Boston, Massachusetts. Hauptthemen laut MEDLINE: Length of Stay, Emergency Service, Hospital, Troponin, Acute Coronary Syndrome. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance High-sensitivity cardiac troponin (hs-cTn) assays are the diagnostic standard for acute coronary syndrome but present significant implementation and workflow complexity.

Objective

To evaluate whether implementation of a structured, electronic health record (EHR)–integrated hs-cTn pathway was associated with changes in emergency department (ED) length of stay (LOS) and serial troponin testing times. Design, Setting, and Participants This retrospective quality improvement study compared preimplementation conventional cTn assay (June 1, 2021, to March 31, 2022) with a postimplementation integrated hs-cTn pathway (June 1, 2022, to March 31, 2023) in 4 urban EDs within a single health system. Participants were adults (aged ≥18 years) presenting with chest pain and at least 1 troponin assay result. Data analysis was performed from April to September 2024. Exposures Implementation of an hs-cTn assay within an EHR-integrated clinical pathway. Main Outcomes and Measures The primary outcome was ED LOS, defined as time from patient registration to ED departure. Secondary outcomes included time from first clinician evaluation to disposition (discharge or admission) and interval from the first troponin assay order to the second troponin assay result in patients with serial assays.

Results

Of the 16 094 patient encounters analyzed (9151 [56.9%] female; mean [SD] age, 49.5 [17.4] years), 8486 (52.7%) were in the hs-cTn and 7608 (47.3%) were in the conventional cTn cohort. Overall, hs-cTn implementation with workflow integration was associated with decreased mean ED LOS, from 6.18 (95% CI, 6.10-6.26) hours to 5.64 (95% CI, 5.57-5.71) hours. Compared with conventional cTn, implementation of the hs-cTn pathway was associated with shorter mean ED LOS in admitted patients (9.60 [95% CI, 9.35-9.87] hours vs 10.50 [95% CI, 10.22-10.78] hours; P = .003) and discharged patients (5.02 [95% CI, 4.96-5.08] hours vs 5.33 [95% CI, 5.26-5.40] hours; P = .006). Pathway implementation was also associated with shorter time from evaluation to disposition in patients receiving 2 or more troponin measurements (5.06 [95% CI, 4.97-5.15] hours vs 6.68 [95% CI, 6.52-6.85] hours; P < .001) and time from first troponin order to second troponin result in both admitted patients (3.18 [95% CI, 3.11-3.25] hours vs 5.16 [95% CI, 5.01-5.31] hours; P < .001) and discharged patients (2.78 [95% CI, 2.75-2.82] hours vs 4.54 [95% CI, 4.46-4.62] hours; P < .001). Conclusions and Relevance In this quality improvement study, an EHR-integrated hs-cTn pathway was associated with significantly reduced ED LOS and, in patients with serial troponin measurements, reduced time from evaluation to disposition and reduced time to serial assay results. The findings suggest this structured EHR approach may mitigate operational challenges of hs-cTn adoption and could serve as a scalable model to improve ED efficiency for patients with chest pain.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Length of StayEmergency Service, HospitalTroponinAcute Coronary SyndromeCritical PathwaysHumansFemaleRetrospective StudiesMiddle AgedMaleQuality ImprovementAgedElectronic Health RecordsAdultChest Pain

Substanzen

Troponin

Autor:innen und Institutionen

  • Department of Emergency Medicine, Beth Israel Lahey Health System, Boston, Massachusetts.
  • Department of Pathology and Laboratory Medicine, Hospital of the University of Pennsylvania, Philadelphia.
  • Department of Emergency Medicine, Penn Medicine, Philadelphia, Pennsylvania.
  • Department of Internal Medicine, Inova Health, Fairfax County, Virginia.
  • Penn Medicine, Philadelphia, Pennsylvania.
  • Corporal Michael J. Crescenz VA Medical Center, Philadelphia, Pennsylvania.

Zitieren

APA

Jia, L. Z., Israelyan, N., Shofer, F. S., Saleh, S., Moon, J., Epps, M., Iocca, J., Foster, S., Adusumalli, S., Bierl, C., & Hemmert, K. (2026). High-Sensitivity Troponin Pathway and Emergency Department Length of Stay. JAMA Network Open, 9(11), e2642980. https://doi.org/10.1001/jamanetworkopen.2026.42980

Vancouver

Jia LZ, Israelyan N, Shofer FS, Saleh S, Moon J, Epps M, et al. High-Sensitivity Troponin Pathway and Emergency Department Length of Stay. JAMA Network Open. 2026;9(11):e2642980. doi:10.1001/jamanetworkopen.2026.42980

BibTeX
@article{Jia2026,
  author = {Jia, Leon Z and Israelyan, Narek and Shofer, Frances S and Saleh, Sameh and Moon, Jeffrey and Epps, Mika and Iocca, Joy and Foster, Sean and Adusumalli, Srinath and Bierl, Charlene and Hemmert, Keith},
  title = {High-Sensitivity Troponin Pathway and Emergency Department Length of Stay},
  journal = {JAMA Network Open},
  year = {2026},
  volume = {9},
  number = {11},
  pages = {e2642980},
  doi = {10.1001/jamanetworkopen.2026.42980}
}
Kostenlos starten →