EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access

Neonatal Ventilation Training Using a Low-Cost, High-Fidelity Simulator in a Low-Resource Setting

Davide Mocellin, Sabina Maglio, Mary-Winnie Nanyaro, Paolo Belardi, Martina Borellini, Elizabeth H Shayo, Amerigo Ferrari, Benjamin Mfaume, Nyanda Ntinginya, Selene Tognarelli, Arianna Menciassi

JAMA Network Open · 2026

DOI: 10.1001/jamanetworkopen.2026.33261 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift JAMA Network Open, 2026. Verfasst von Davide Mocellin und 10 weiteren Autor:innen. Beteiligte Einrichtung: The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy. Hauptthemen laut MEDLINE: Respiration, Artificial, Simulation Training, High Fidelity Simulation Training. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance Neonatal mortality rates in sub-Saharan Africa remain high (26 per 1000 live births). Limited access to advanced respiratory support and shortage of trained health personnel make manual ventilation a lifesaving, yet high-risk, essential competence. Simulation-based training may strengthen neonatal ventilation skills, but evidence on acceptability and educational effectiveness of low-cost, high-fidelity simulators in resource-limited settings is limited.

Objective

To build local capacity in manual neonatal ventilation and to assess acceptability and educational effectiveness of different simulator configurations across participants with varying levels of clinical experience. Design, Setting, and Participants This randomized clinical trial was conducted from June 17 to 20, 2025, at a regional-level referral hospital in Tanzania. Participants included undergraduate medical students with no prior neonatal ventilation experience and local health professionals.

Interventions

Participants were randomly assigned to 1 of 3 simulator configurations (medium-fidelity passive setup with no feedback, high-fidelity passive setup with mechanical feedback, and high-fidelity active setup with mechanical and sensors feedback). All participants received a 4-day training program consisting of theoretical lectures, hands-on simulation training with 1 of the 3 simulator configurations, and a standardized final evaluation. Main Outcomes and Measures The primary outcome was objective ventilatory performance measured by the simulator during the hands-on sessions, defined as ventilation frequency and peak inspiratory pressure (PIP). Secondary outcomes included tutor-based performance evaluation, theoretical knowledge assessment in a 10-item questionnaire, and practical ventilation performance evaluation in a 12-item checklist. Tertiary outcomes were user-reported acceptability, perceived usefulness, perceived ease of use, behavioral intention, and simulator fidelity, assessed using the Technology Acceptance Model (TAM).

Results

Both students (42 participants; median [IQR] age, 21 [20-22] years; 25 female [59.5%]) and health professionals (37 participants; median [IQR] age, 26 [23-29] years; 30 female [81.1%]) demonstrated improvements in theoretical knowledge (posttraining vs pretraining mean [SE] score [maximum 10 points]: students, 8.88 [0.13] vs 8.29 [0.17]; P < .001; health professionals, 9.14 [0.13] vs 8.65 [0.17]; P = .03) and practical ventilation performance following training (mean [SD] evaluation score [maximum 12 points]: students, 10.4 [0.7]; health professionals, 10.2 [0.9]). Training effectiveness varied by simulator configuration and participant experience. Among students, a medium-fidelity configuration was associated with improved ventilation frequency and PIP, whereas among health professionals, an active high-fidelity configuration supported improved performance during hands-on training. TAM scores confirmed a high simulator acceptability with no differences between groups. Conclusions and Relevance In this randomized clinical trial of an adaptable, low-cost, high-fidelity neonatal ventilation simulator, effective training across heterogeneous learner groups in a resource-limited setting was supported; tailoring simulator feedback to learners’ baseline experience enhanced training effectiveness. These findings support the feasibility of scalable, simulation-based neonatal ventilation training in low-resource environments. Further research on skill retention, transfer to clinical practice, and neonatal outcomes are needed. Trial Registration ClinicalTrials.gov Identifier: NCT07665164

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiration, ArtificialSimulation TrainingHigh Fidelity Simulation TrainingHumansTanzaniaFemaleResource-Limited SettingsInfant, NewbornMaleClinical CompetenceAdult

Autor:innen und Institutionen

  • The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
  • National Institute for Medical Research, Dar es Salaam, Tanzania.
  • Doctors with Africa CUAMM, Iringa, Tanzania.
  • Division of Obstetrics and Gynecology, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy.
  • Tosamaganga Regional Referral Hospital, Iringa, Tanzania.

Zitieren

APA

Mocellin, D., Maglio, S., Nanyaro, M. W., Belardi, P., Borellini, M., Shayo, E. H., Ferrari, A., Mfaume, B., Ntinginya, N., Tognarelli, S., & Menciassi, A. (2026). Neonatal Ventilation Training Using a Low-Cost, High-Fidelity Simulator in a Low-Resource Setting. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2026.33261

Vancouver

Mocellin D, Maglio S, Nanyaro MW, Belardi P, Borellini M, Shayo EH, et al. Neonatal Ventilation Training Using a Low-Cost, High-Fidelity Simulator in a Low-Resource Setting. JAMA Network Open. 2026. doi:10.1001/jamanetworkopen.2026.33261

BibTeX
@article{Mocellin2026,
  author = {Mocellin, Davide and Maglio, Sabina and Nanyaro, Mary-Winnie and Belardi, Paolo and Borellini, Martina and Shayo, Elizabeth H and Ferrari, Amerigo and Mfaume, Benjamin and Ntinginya, Nyanda and Tognarelli, Selene and Menciassi, Arianna},
  title = {Neonatal Ventilation Training Using a Low-Cost, High-Fidelity Simulator in a Low-Resource Setting},
  journal = {JAMA Network Open},
  year = {2026},
  doi = {10.1001/jamanetworkopen.2026.33261}
}